Specifications

Users Manual: MD-CP42AUPG-MED
© 2011 Richardson Electronics GmbH
Division Canvys
25
1.6 ALSON/OFF.(ID=0x0C)
command 04 03 0C CK1
reply: 04 0C 00 CK2 - ALS OFF.
reply: 04 0C 01 CK2 - ALS ON.
1.7 Scaling Control(ID=0x09)
command 04 03 09 CK1
reply: 04 09 00 CK2 - 1:1.
reply: 04 09 01 CK2 - Aspect.
reply: 04 09 02 CK2 - FULL.
1.8 PIP/SWAP Control(ID=0x08)
command 04 03 08 CK1
reply: 04 08 00 CK2 - PIP OFF.
reply: 04 08 01 CK2 - PIP ON.
reply: 04 08 02 CK2 - SWAP.
1.9 Power On/OFF Control(ID=0x07)
command 04 03 07 CK1
reply: 04 07 00 CK2 - Power OFF.
reply: 04 07 01 CK2 - Power ON.
1.10 Lamp Status(ID=0x25)
command 04 03 25 CK1
reply 04 25 DD CK2 - Lamp sensor Data
1.11 Temp Status(ID=0x26)
command 04 03 26 CK1
reply 04 26 DD CK2 - Temperature sensor Data
2.0 Control Write command:
command format: 05 04 ID DD CK
reply command format: 03 0C F1
DD:control data value
CK:checksum for checking command weather valid. CK=~(05+04+ID+DD)+1
2.1 Color Mode status (ID=0x01)
command 05 04 01 00 CK -set to Gamma OFF Mode
command 05 04 01 01 CK -set to Gamma2.0 Mode
command 05 04 01 02 CK -set to Gamma2.2 Mode
command 05 04 01 03 CK -set to Gamma1.8 Mode
command 05 04 01 04 CK -set to DICOM Mode
command 05 04 01 05 CK -set to Calibration Mode
reply: 03 0C F1 - ack.
2.2 Color temperature (ID=0x03)
command 05 04 03 00 CK - Cool
command 05 04 03 01 CK - Neutural
command 05 04 03 02 CK - warm
command 05 04 03 03 CK - User.
reply: 03 0C F1 -ack.