Section 7 – Displaying and Responding to Profit Optimizer Messages
7.4 Dictionary of Profit Optimizer Messages
100 Profit Optimizer User's Guide 1/00
Honeywell Inc.
Profit Optimizer
Messages
180-185
180
Message: Reserved
Meaning Suggested Response
181
Message: Some Profit Controllers (RMPCTs) are inactive
Warn
Meaning Suggested Response
Activate all Profit Controllers (RMPCTs)
182
Message: Some Critical Profit Controllers (RMPCTs)are not ON
Warn
Meaning Suggested Response
All critical Profit Controllers (RMPCTs) should be ON if the
Optimizer (DQP) is ON, they should be ON / WARM if the
Optimizer is WARM
183
Message: Too many bad brdg inpts, prdctions reset
Error
Meaning Suggested Response
The number of consecutive bad BDV inputs is
greater than the max BVD Bad Re_init
184
Message: Too many bad brdg inpts, turning DQP off
Error
Meaning Suggested Response
The number of consecutive bad BDV inputs is greater
than the max limit
When BDVs are ok, turn Profit Optimizer (DQP) back
on.
185
Message: Too many bad crit brdg outputs, DQP off
Error
Meaning Suggested Response
The number of consecutive bad BDV outputs is
greater than the max limit
When BDVs are ok, turn Profit Optimizer (DQP) back
on.