Specifications

EM - 8 Electronic Modules Ver. 0002
EM.1.2 GENERAL CHARACTERISTICS OF THE REGENERATIVE
POWER SUPPLIES
XPS-25 Module XPS-65 Module
Power supply (Vmains)
Three-phase 50/60 Hz, with a voltage range
between 380Vac -15%. and 460Vac +10%
Mains power consumption 38 Amp -RMS- 100 Amp -RMS-
Maximum connection cable section
16 mm
2
50 mm
2
Voltage of the Power Bus. VBUS
NOM
540 Vdc / 650 Vdc
Rated (peak) output current (*)
45 Amp (100 Amp, 1 sec) 120 Amp (120 Amp, 1 sec)
Rated (peak) output power
25 kW (55 kW, 1 sec) 65 kW (108 kW, 1 sec)
Regenerating circuit on/off voltage
Vmains x 1.414 + 30V
Rated regenerated current (returned to mains) (*)
25 Amp -RMS- 62 Amp -RMS-
Rated regenerative power (returned to mains)
16 kW 41 kW
Related Choke CHOKE XPS-25 CHOKE XPS-65
Choke-Drive Cable (max. length: 2 m (80 inches)) 16 mm
2
50 mm
2
Output voltage of the Auxiliary Power Supply
24 Vdc ± 5%
Maximum current supplied 8 Amps at 24 Volts (192 watts)
Mains consumption for 24 Vdc generation 0.75 Amp (380 Vac) 0.63 Amp (460 Vac)
Internal Ballast resistance (Power (*))
18 Ohms (520 W) 9 Ohms (1800 W)
Energy pulse that could be dissipated
18 kWs (0.6 sec) 50 kWs (1 sec)
Ballast circuit On/Off voltage
765 Vdc / 755 Vdc (616 Vdc / 608 Vdc (***))
Minimum external Ballast resistance
18 Ohms 9 Ohms
Filter capacity 1175 microF, 900 Vdc 2115 microF, 900 Vdc
Energy stored in the capacitors
0.5 · C · V
2
Maximum "System OK" contact voltage
125 Vac, 150 Vdc
Maximum "System OK" contact current
2 Amp
Module width
194 mm (7.64 inches) 234 mm (9.21 inches)
Module weight
14 Kg (31 lbs) 19 Kg (42 lbs)
Power dissipated at maximum load
180 W 350 W
Ambient temperature (*) 5°C / 45°C. (41°F / 113°F)
Storage temperature -20°C / 60°C (-4°F / 140°F)
Humidity less than 95% (non-condensing at 45°C / 113°F)
Maximum altitude without loss of features 1000 meters (3281 ft) above sea level
Operating vibration 10..60 Hz, 0.1..5 G, 2 hr
Shipping vibration 60..300 Hz, 5 G, 2 hr
Sealing IP20
Protections
Overvoltage, Overcurrent,
ambient temperature, hardware error.
(*) See derating curves in case of high temperatures
(***) When the module is set for Vmains = 380 Vac