Specifications
AM - 30 Asynchronous Motors Ver. 0002
AM.14 IDENTIFICATION BOARD
The identification plate of each motor has the shape shown in the next figure.
AM.15 REGISTRATION NUMBERS FOR SPM MOTORS
Many of the Drive's Software parameters are directly related to the characteristics of the
motor it governs; see appendix A. For the Fagor motors in this manual, the software knows
the values that must be assigned to those parameters.
Motors equipped with Encoder (sales reference E0, E1) have their reference stored in
their electronic memory so the parameter setting at the drive is done automatically.
See the GSU chapter. In a manual setting, the drive must be "told" which motor is going to
govern.
Appendix C shows the codes of this reference for asynchronous motors. These identifiers
(motorid) are followed by the version release identifier (Rel) in all cases.
For example: SPM112LE.E1.00000.1-C
3 Phase
AC Induction Motor
Fagor Automation
S. Coop. (Spain)
Type SPM 112LE.E1.00000.1 Rel. C SN 96L 1078 Year 1999
S1
Pn 7.5 kW
In 24 A
S6
P 11 kW
I 34.5 A
Vn 330 Vac
Nm 47.7 Nm
Slip 55 rpm
Hz 50
Conn.
IP 54
Speed Nn/Nmax 1500/7500 rpm
Magnetizing current 11.4 A
Resistance (ph/ph) 0.44 Ω
Inductance (ph/ph) 5.3 mH
Electric Fan type R2E190 Ph1 V 220 A 0.35 Hz 50/60 IP54
Transducter type Stegman
Brake type
W 53 kg
M V1/V5
I. cl F
B. cl S