Specifications
Parameters, Variables and Commands Ver. 0002 A - 33
OV10 O (F1410) DigitalOutputs
Function: The OV10 variable contains a binary coded numeric value which represents the
status of the digital outputs present in slot SL1.
• If slot SL1 is occupied by connectors X6 and X7, these outputs correspond to
parameters OP10-OP13. When working with the PLC, these outputs represent
PLC resources O1-O4.
• If slot SL1 is occupied with any of the I/O cards (16DI-8DO, 8DI-16DO), OV10
refers to PLC resources O1-O16.
When reading: Value of the digital outputs.
When writing: Values forced onto those digital outputs which do not have
functions associated by parameters OP10-OP13.
Valid values: 0..65535 ($FFFF)
Default value: 0 (unassigned)
Example: We read that OV10 = 11 whose binary code is 1011. This means that outputs 1, 2
and 4 of connector X6 are active and output 3 is inactive. In other words, that contacts
(6,7), (8,9) and (12,13) are closed and contact (10,11) is open.
If we write that same data, we will be forcing the contacts to those positions, as
long as OP10-OP13 are not associated.
Version: Operative from version 02.01 on. Renewed in version 04.01
OV11 O (F1413) DigitalOutputsCh2
Function: The OV11 variable contains a binary coded numeric value which represents the
status of the digital outputs present in slot SL2.
• At the PLC, the value of OV11 refers to resources O17-O32
When reading: Value of the digital outputs.
When writing: Values forced upon the digital outputs.
Valid values: 0..65535 ($FFFF)
Default value: 0 (unassigned)
Example: We read that OV11 = 35 whose binary code is 00100011. This means that resources
O17, O18 and O22 are active and the rest are inactive.
If we write this same data, we will be forcing the activation or deactivation of those
resources.
Version: Operative from version 04.01 on.
8DI-16DO
1
13
1
11
1
9
A1
1
9
I3
I2
I1
1
9
1
9
1
9
I7
I6
I5
I4
O11
O10
O9
O8
O15
O14
O13
O12
O3
O2
O1
O7
O6
O5
O4
I3
I4
I1
I2
O4
O3
O2
O1
I19
I18
I17
16DI-8DO
1
9
1
9
1
9
I23
I22
I21
I20
I27
I26
I25
I24
I31
I30
I29
I28
O19
O18
O17
O23
O22
O21
O20
Drive Module
(
example
)
I32
I8
O16O24
I19
I18
I17
I23
I22
I21
I20
I24
O27
O26
O25
O31
O30
O29
O28
O32
SL2 SL2SL1 SL1
Drive Module
(
example
)
8DI-16DO
1
9
O19
O18
O17
O23
O22
O21
O20
O24
X6
X7
X8
X9
X10X13
X12
X11
X8
X9
X10
P2
P1