Specifications
DS - 14 Design Ver. 0002
Selection Criteria.
1. The "Power Supply" module must be capable of supplying the power required by
the set of servo system connected to it.
NEVER connect the power supplies in parallel.
2. The "Power Supply" module must be able to supply the peak power required by the
set of servo systems connected to it.
NEVER connect the Power Supplies in parallel.
Rated
Power
(S1)
kW
< 25
< 65
> 65
Power
Supply
Module
Reference
PS-25A, PS-25B or XPS-25
PS-65A or XPS-65
(*)
Power Supply needed: ( + ) = (kW)
(*) Until reaching the needed power from the Power Supply
Very important: When using two Power supplies on the same machine, they have to form two separate groups
with their respective drives. Only the Sercos ring, if there is one, may be common to both groups.
1 2
First Criterion.
The "Power Supply" module must be capable of supplying the power
required by all the Drive + Motor combinations connected to it.
Peak
Power
kW
< 75
< 195
> 195
Power
Supply Module
Reference
PS-25A or PS-25B
PS-65A
(*)
Peak Power Supply needed: ( + ) = (kW)
(*) Until reaching the needed peak power from the Power Supply
Very important: When using two Power supplies on the same machine, they have to form two separate groups
with their respective drives. Only the Sercos ring, if there is one, may be common to both groups.
3 2
Second Criterion.
The "Power Supply" module must be capable of supplying the
peak power
required by all the Drive + Motor combinations connected to it.
kW
< 55
< 108
> 108
Reference
XPS-25
XPS-65
(*)
Regenerative