Specifications

AP - 16 Applications Ver. 0002
Any parameter may be edited at any time (eight sets and eight gear ratios). The Backup and
Restore operations affect the whole parameter table.
Each time, only one of those "sets" and one of those "gear ratios" determine the operation of
the system . They are the Set and Gear ratio active at the time.
All Set-GearRatio combinations are possible.
Important parameters:
GP4, number of useful sets GP6, number of useful gear ratios
GV21, active set GV25, Active gear ratio.
The drawing shows an example:
Parameters GP4 and GP6 limit the number of sets and gear ratios that can be activated.
For example, with GP4=4 the values of Active Set are limited to between 0 and 3.
Important:
Assigning a motor ID to the GV10 variable resets the whole parameter table to their
default values. Particularly, GP4=1 and GP6=1 thus leaving Set 0 and Gear Ratio 0 as
the only ones that can activated.
Turning the drive back up sets GV21=0 and GV25=0.
The next sections describe the operation of these two subsets.
Set 7
SP10.7
SP100.7
Set 6
SP10.6
SP100.6
Set 5
SP10.5
SP100.5
Set 4
SP10.4
SP100.4
Set 3
SP20.0
SP21.3
SP40.3
SP41.3
CP20.3
IP1.3
SP1.3
.......
SP10.3
SP80.3
SP100.3
SP60.0
SP65.3
.......
Set 2
SP10.2
SP100.2
Set 1
SP10.1
SP100.1
Parameter Table
Set 0
SP20.0 SP21.0 SP40.0 SP41.0
CP20.0 IP1.0
SP1.0 ....... SP10.0
SP80.0 SP100.0SP60.0 SP65.0.......
AP1 BV1 ......
..........................
XV1 XV2......
.........................
&&
Gear Ratio 5
NP122.5NP121.5
NP123.5
Example:
GP4=8 GV21=3
GP6=6 GV25=1
General parameters
General parameters
ActualSet
Gear Ratio 4
NP122.4NP121.5
NP123.5
Gear Ratio 3
NP122.3NP121.5
NP123.5
Gear Ratio 2
NP122.2NP121.5
NP123.5
Gear Ratio 1
NP122.1
NP121.1
NP123.5
NP122.0NP121.0NP121.0
Gear Ratio 0
NP123.0
ActualGearRatio