Specifications

GSU - 12 Common Setup Ver. 0002
User motor.
When installing a non-Fagor motor (user motor) or to get access to certain "motor
parameters", MP1 -S00141- MotorType must be loaded with a value starting with "0", for
example, 0supermotor.
The drive software only admits one user motor. To keep the parameter tables of several
"user motors", the various parameter transferring functions must be used. See the
previous section on "transferring parameter tables".
Save to Flash.
Remember that after any of the identification processes described earlier, the motor reference
is stored in RAM memory of the drive and it still has no effect on how it runs. Therefore:
After the adjustment by any of the previous methods, it is necessary to Save the
parameter table into Flash Memory.
On power-up or after a Reset, the system will check that the value given to
MP1 -S00141- MotorType (manually or automatically) is correct. In other words, that the motor
and the drive are compatible with each other. The error codes will identify the mistake made.