Specifications

IN - 2 Installation Ver. 0002
IN.1 SECURING ALL THE ELEMENTS
1.- Prepare the fixtures in the electrical cabinet. See the EM chapter -dimensions-.
2.- Unpack the system motors and modules
3.- Mount each of the motors on the machine
4.- Install all the modules making up the Servo-Drive System in the electrical cabinet
IN.1.1 PLACEMENT OF THE SERVO DRIVE SYSTEM
Ambient conditions:
Never install the Servo-Drive System in places where there are corrosive
gases.
Always install it well away from areas with unfavorable atmospheric
conditions, avoiding exposure to oil, water, hot air, high humidity,
excessive dust or metal particles.
Especially:
When installing the RM-15 outside the electrical cabinet, it must be done
away from water, coolant, chips, etc. since the module only guarantees a
sealing protection of IP2x.
The sealing degree of the ER resistors is: IP55.
It is entirely up to the installer to take care of these matters.
Mechanical conditions:
The Drive system must be mounted vertically in the electrical cabinet. To secure it, use the
holes and slots made for that purpose.
Vibrations should be avoided. If necessary use securing means made of a material which
absorbs or minimizes vibrations.
To facilitate heat removal, the equipment should be installed so as to leave at least 80 mm
(3.15 inches) above and below it. See figure.
Important:
Mount the Drive Module of greater power
next to the Power Supply module and use
the same criteria for the rest of the Drive
Modules.
>80 mm (3.15")
>80 mm (3.15")
Air
Power Supply
Drive
Drive
Drive