Specifications
Electronic Modules Ver. 0002 EM - 51
Very important: In case of microsurges or total mains power outage, this module guarantees
the stability of the 24 Vdc for as long as the emergency stop of the motors lasts. This is an
absolute must in order to comply with the "CE" requirement for the machine.
This auxiliary power supply has three LEDs to indicate the operating status.
- Red led1: Output overvoltage. The power supply has exceeded 28 Vdc and it is not working.
- Red led2: Output overcurrent. The power supply has exceeded 10 Amps and its output
voltage is less than 24 Vdc.
- Green Led: Running OK.
When the power supply quits working due to overvoltage, the module has push-button for
system reset.
The last section of this chapter shows the
module dimensions.
This APS 24 power supply is to be used to supply to the electrical control
circuits and signals to run the drive.
It MUST NEVER be used for the brake of a motor.
The brake may generate voltage peaks that could damage the module.
EM.9.1 APS 24 CONNECTORS