User Guide
Appendix
118
Axcess Programming Language
Standard:
PROGRAM_NAME='AMX01, BOARDROOM, SO#99999, REV2, XXX/BETA'
(* DATE:04/08/95 TIME:01:23:45 *)
(* SYSTEM TYPE: ENHANCED MASTER V3.500 *)
(*********************************************************)
(* REV2: ADDED EL+ *)
(* FIXED PROJ POWER GETTING OUT OF SYNC *)
(* REV1: CHANGED IR CODES FOR TUNER *)
(*********************************************************)
(*********************************************************)
(* DEVICE DEFINITIONS GO BELOW *)
(*********************************************************)
DEFINE_DEVICE
5. Use similar device numbers for devices on the AXLINK buss in every system you program.
Not recommended:
SLD = 100
RELAYB = 101
FLOPPY = 102
SWP = 103
TP = 104
Standard:
SLD = 96 (* AXB-SLD - MOST BOX DEVICES START AT 96 *)
RELAYB = 97 (* AXB-REL8 *)
FLOPPY = 127 (* AXB-FD - FLOPPY DRIVES AT 127,126, *)
SWP = 128 (* AXP-SP+ - ALL OTHER DEVICES START HERE *)
TP = 129 (* AXP-EL+ *)
6. Use the following prefixes when naming AXLINK buss devices:
TP AXP-EL, AXP-EL+, AXP-LC, AXP-T/S, AXP-TLC
SWP AXP-SP, AXP-SP+
MSP AXP-MSP8, AXP-MSP16, AXP-MSP24, AXP-MSP32
SLD AXB-SLD, AXC-SLD, AXC-SAV
RADIO AXR-RF
IR AXR-IR, AXR-IRSM, AXC-RCVI
MLCD AXP-MLCD
CPI AXP-CPI, AXP-CPIL, AXP-CPI8
FLOPPY AXB-FD
SPL AXP-SPL4
AI8 AXP-AI8