User Guide
Pre-Installation
5
AXC-TEMP Temperature Control Card and RTS1 Room Temperature Sensor
RTS1 Preparation
To install the RTS1 units:
1. Wire RTS1 units 1 - 4. Refer to Wiring the RTS1 for additional information.
2. Check the temperature.
! If the panel has a display, check the temperature readings on the system Wiring control
panel. The temperature readings will change when the room temperature changes by a
half degree.
! If the panel does not have a display, check the variables in Axcess.
Wiring the RTS1
Use Belden 8723 or equivalent cable. When an application or code requires plenum-rated cable, use
Belden 88723 or equivalent cable.
Call AMX Technical Support for any installations that require a wire run of more than 100 feet.
FIG. 6 RTS1 circuit connections
2.75" (69.9 mm)
w/ front cover on
4.5"
(114.3 mm)
RTS1 backplate
Wire feed hole
RTS1 circuit board
AXlink connector
From left to right:
GND, OUT, PWR
RTS1 depth is 0.9"
(22.9 mm) with the
front cover installed