MAX 5510 PRO ACRegenerator Owner’s Manual ™ ® POWER MAX® 5510 PRO MODEL M5510-PRO 1690 Corporate Circle, Petaluma CA 94954 • www.panamax.
™ MAX 5510 PRO ACRegenerator Owner’s Manual ® Thank you for purchasing this MAX® 5510 been specifically engineered to enhance This is truly a Firewall for Noise™! Pro, ACRegenerator™! You now own one the performance and life expectancy of With power this clean, your audio/video of the finest line conditioning and power high-end Audio/Video entertainment gear. or home theater system will finally be protection products on the market today.
TABLE OF CONTENTS Before You Begin.........................................................1 Convenience Lamp................................................7 Introduction.................................................................2 Voltage Sense Triggers..........................................7 Connection Diagram....................................................3 Isolation Transformer Circuit Breaker.....................8 Feature Overview......................................................
INTRODUCTION Your Audio/Video components are constantly being bombarded by electromagnetic interference (EMI) and radio frequency interference (RFI) through their power cords. This contaminated power can affect analog and digital equipment and will degrade the overall performance of your entire system. Digital components can also introduce noise on their AC power lines, which can interfere with the performance of analog components.
CONNECTION DIAGRAM STEP 1 Typical AC Power, RS232 and 12V Trigger Connections DVD AMPLIFIER HOME AUTOMATION CONTROL CD PLAYER AUDIO VIDEO RECEIVER CIRCUIT BREAKER USB LED LIGHT IN R ALWAYS ON OUTLETS ISOLATED OUTLETS AC INLET TRIGGER DELAY 12V TRIGGER IN OUT TRIGGER ENABLE RS-232 Control IN G IN B ISOLATED OUTLETS DELAY HIGH CURRENT OUTLETS HIGH CURRENT OUTLETS DELAY GROUND LUG PROPERLY GROUNDED AC OUTLET LINE LEVEL AUDIO / VIDEO OUT OUT OUT OUT OUT CIRCUIT BREAKER IN H IN V LAN / T
FEATURE OVERVIEW 1. Power Switch and LED: 2. Meter Lights Switch: Pushbutton; activates a turnon or shutdown sequence for the Isolated and High-Current outlets. The Green LED will be illuminated when the unit is plugged into an AC outlet and the power switch is in the “ON” position. The LED flashes during the outlet turn-on and turn-off delay periods. Pushbutton; controls brightness of the Ammeter and Voltmeter backlighting. Cycles among five settings; High Blue, Low Blue, High Amber, Low Amber, OFF 3.
FEATURE DETAILS The indicators are: POWER Power Switch and LED Indicator: Momentary Pushbutton (non-locking); activates a turn-on or shutdown sequence for the Isolated (Switched) and High-Current outlet banks. The Green LED will be illuminated when the unit is plugged into an AC outlet and the power switch is in the “ON” position. Switched Outlets: Green LED. This light indicates the status of the Isolated (Switched) and HighCurrent outlet banks.
FEATURE DETAILS (continued) Isolated/Switched Outlet Bank: Sequential Startup/Shutdown: Complex audio/video systems may be susceptible to voltage transients generated internally at startup/shutdown if all of the equipment is powered on or off at the same time. This can cause speaker “thumps” which are not only annoying but can also damage the speakers.
FEATURE DETAILS (continued) DC Triggers: Filtered Outlet Banks 1 & 2: ALWAYS ON OUTLETS ISOLATED OUTLETS NT OUTLETS ISOLATED OUT RS232 CON 12V TRIG IN Four outlets (two banks / two outlets per bank) are fed through separate “Balanced, Double L” noise filtration circuits. These circuits are designed to eliminate the AC contamination that is most detrimental to the performance of analog or video components like stereo receivers, VCRs or televisions.
FEATURE DETAILS (continued) Circuit Breakers: OUT OUT OUT OUT IN Telephone/LAN Line Protection: OUT SATELLITE 2 MAIN BREAKER ALWAYS ON OUTLETS ISOLATED OUTLETS HIGH CURRENT OUTLETS GROUND IEC 320 C13 120V/15A ALWAYS ON OUTLETS ISOLATED OUTLETS BREAKER SATELLITE 1 LINE LEVEL AUDIO / VIDEO OUT OUT OUT OUT OUT USB LED LIGHT RS232 CONTROL IN IN G IN R 12V TRIGGER IN OUT IN B IN H IN V IN TRIGGER DELAY-ON HC OUTLETS DELAY OUT CATV LAN / TELCO TRIGGER ENABLE OUT SATELLITE 2 SWI
FEATURE DETAILS (continued) The MAX 5510-Pro requires line voltage to return to within the safe operating range for 10 seconds before returning to normal operating mode. This is referred to as "Over/Under Voltage Recovery". The safe operating range is considered 5V above the under-voltage threshold and 5V below the over voltage threshold. Once this safe operating range is reached, the MAX 5510-Pro will perform the following functions: Patented Over/Under Voltage Protection: 1.
MAX PRO-SERIES RS-232 COMMAND SPECIFICATIONS 1. OVERVIEW The Panamax Pro-Series product family has a RS232 interface that allows it to communicate with a wide variety of equipment. The purpose of this document is to outline the command set used to communicate with the Pro-Series (PS) products. Commands and responses are in the form of ASCII character STRINGS TERMINATED with ASCII 13, line feed (ASCII 10) or NULL (ASCIØ). DB9 Pinout Diagram 5 4 3 2 1 6 7 8 9 PIN NO. 1 2 3 4 5 6 7 8 9 2.
ISOLATED vs. BALANCED POWER Power Modes in the MAX® 5510 Balanced Power Single-phase grounded-neutral power Supply The standard method of residential power delivery in the U.S. The neutral, or "grounded" conductor, is bonded to the earth, or "grounding" conductor. The N-G panel bond creates a severe imbalance with respect to common-mode currents, which can lead to "hum" in A/V equipment.
TROUBLESHOOTING My power cable does not reach the wall outlet. Can I use any extension cord to make it reach? The 6 Amp, Isolation Transformer circuit breaker continually trips. What is the problem? I connected the LED Convenience Lamp and the lamp will not work. What is the problem? No, Panamax extension cords are the only extension cords that you can use while keeping your warranty valid. The four Isolation Transformer outlets share the 720 VA Isolation transformer for their power source.
PANAMAX, the Panamax logo and MAX are registered US trademarks of Panamax. ACRegenerator and SignalPerfect are trademarks of PANAMAX. SIDACtor is a registered US trademark of Teccor Electronics, Inc. TiVo is a trademark of TiVo, Inc.
90 Corporate Circle, Petaluma, CA 94954 Tel: (707) 283-5900 Fax:: (707) 283-5901 Email: sales@panamax.com Web: www.panamax.