nXa-PDU-1508-8 control system accessories
SPECIFICATIONS
DIMENSIONS (HWD)
•13/16"x17"x911/16(3.0cmx43.2cmx9.7cm)
•RU:1
POWER
•
Poweredvia100-240VAC,50-60HzmainspoweronanIEC-320C-14connector
•Requiredvoltage=100to240VAC,47-63Hz
•ACCurrent
-Input:12AMPS@110V-120V
-Input:10AMPS@220V-240V
-Outputs:10AMPSSingleOutlet@110VAC,12AMPSMaxUnitOutput
@110VAC
-Outputs:8AMPSSingleOutlet@220VAC,10AMPSMaxUnitOutput
@220VAC
FRONT PANEL COMPONENTS
MASTER RESET PUSHBUTTON
•TheMasterResetpushbuttonisamomentarybreakerresetswitchforthe
AMX Master power connection
•Trippageoftheresetswitchcausesa0.5secondtoggleontheAMXMaster
AxLinkpowerline
AXLINK STATUS LED:
GreenLEDlightstoindicateAxLinkcommunicationactivity
•ON-power,nomasterconnection
•OFF-nopower
•Blink-powered,communicatingwithmaster
OUTLET STATUS LEDS
8greenLEDsilluminatewhentheassociatedPowerOutlet(#1-#8)isinuse.
AXLINK BUS STATUS LEDS
2redLEDslighttoindicatestatus(on/off)forAxLinkBusStrips1-2.
TheseLEDsilluminatewhentheassociatedAxLinkBusStrip((#1or(#2)onthe
PDUisinuse.
•AxLinkBusStrip1containsAxLinkconnectors1-4
•AxLinkBusStrip2containsAxLinkconnectors5-8
REAR PANEL COMPONENTS
INTERNATIONAL POWER INLET (1)
•100-240VAC50/60Hz
•ConnectorType:IECC-14,15A@120VAC/10A@240VAC
•Intendedforusewiththeincludedpowercord(USVersionOnly)
INTERNATIONAL POWER OUTLETS (8)
•100-240VAC50/60Hz
•ConnectorType:IECC-13,10A
•Maximumloadperoutlet=10A@120VAC,8A@240VAC
•Maximumloadperunit=15A@120VAC,10A@240VAC
•Providesswitchingofmainspowertoeachoftheeightpoweroutlets.
•MeasurescurrentoneachACpoweroutlet,aswellasthetotalcurrentdrawof
theentirePDU.
AXLINK MASTER CONNECTOR:
•3.5mmPhoenix(4-pin)AxLinkconnectorprovidesconnectivitytotheNetLinx
Master(alwayson).
AXLINK DEVICE CONNECTORS (8):
3.5mmPhoenix(4pin)AxLinkconnectorsprovideconnectivitytouptoeight
AxLinkdevicestwoswitchedbanksoffouroutputseach:
•Bank1containsAxLinkconnectors1-4
•Bank2containsAxLinkconnectors5-8
A13.5VDC,6.5ApowersupplyisprovidedfortheAxLinkbusstrip.ThePDU
measurescurrentdrawoftheAxLinkpowersupply.
REMOTE TEMPERATURE SENSOR (RTS) INPUT
3.5mmPhoenix(2pin)connectorprovidesconnectiontoan(optional)Remote
TemperatureSensor(RTS).TheNXA-PDU-1508-8iscompatiblewiththeENV-
VST-TSFFlushMountIndoorTemperatureSensor,andtheENV-VST-TSOOutdoor
Temperaturesensor.
AXLINK ADDRESS DIP SWITCH
8-positionDIPswitchsetstheAxLinkdeviceaddressfortheunit.
ENCLOSURE
Steel,blackpowdercoatednish
ENVIRONMENTAL
•OperatingTemperature:0°Cto40°C(32°Fto104°F)
•OperatingHumidity:5%to85%,non-condensing
•StorageTemperature:-10°Cto60°C(14°F-14F)
INCLUDED ACCESSORIES
•ENV-VST-TSOViewStatOutdoorTemperatureSensor(FG2050-22)
•EC-320C-13toNEMA5-15Pcable
•Removablerackears
OTHER AMX EQUIPMENT
•ENV-VST-TSFIndoorTemperatureSensor(FG2050-21)
•C13toC14PowerCable(FG10-673-01)
•NEMAtoC14PowerCable(FG10-673-02)
RECOMMENDED ACCESSORIES DESCRIPTION PART # PAGE #
CC-C13-C14 C13 to C14 Power Cable (FG10-673-01) 403