Instruction manual

Programming
48
AXB-PT10/15/30 PosiTrack Camera Controllers
Response mask
Data is automatically sent if the PosiTrack units receive a change request. The response mask
should be disabled if the change request data is not used. Bits in the response mask
(the Return/Respond Strings from the PosiTrack Units table) turn data off.
(1=ON) DATA SENT
(0=OFF) DATA NOT SENT
Response Mask
Bit Data Controlled Default
First byte (MASK1)
7 (msb) RECEIVE STRING 1
6 RECEIVE COMMAND 1
5 CHANNEL CHANGE 1
4 LEVEL CHANGE 1
3BUS LED0
2 (future) 0
1 (future) 0
0 (lsb) (future) 0
Second byte (MASK2)
7 (msb) (future) 0
6 (future) 0
5 (future) 0
4 (future) 0
3 (future) 0
2 (future) 0
1 (future) 0
0 (lsb) (future) 0