Instruction manual

Programming
28
AXB-PT10/30 PosiTrack Camera Controllers
Configuration Commands (Cont.)
FIND HOME
Runs a series of pan/tilt
movements to
recalibrate its
mechanical home.
It then goes to the "Home offset" if it has been defined, if not it goes to the
mechanical "Home".
Syntax:
SEND_COMMAND CAM,"’FIND HOME’"
This command is used within the AxcessX program.
FOCUS PRESET=POS
Sets the FOCUS
voltage output to recall
positional presets
(default).
This is applicable only if the FOCUS SIGNAL=S command is in effect, and the
FOCUS switch is set to the S position (servomotor mode).
Syntax:
SEND_COMMAND CAM,"’FOCUS PRESET=POS’"
The command for FOCUS output to servomotor mode or motor mode MUST be
configured to match the switch settings.
FOCUS
PRESET=SPEED
Sets the FOCUS
voltage output to recall
speed presets.
This is applicable only if the FOCUS SIGNAL=S command is in effect, and the
FOCUS switch is set to the S position (servomotor mode).
Syntax:
SEND_COMMAND CAM,"’FOCUS PRESET=SPEED’"
The command for FOCUS output to servomotor mode or motor mode MUST be
configured to match the switch settings.
FOCUS SIGNAL=M
Sets the FOCUS output
to be a motor output.
This setting corresponds to the M position (motor mode) setting on the FOCUS
switch.
Syntax:
SEND_COMMAND CAM,"’FOCUS SIGNAL=M’"
The command for FOCUS output to servomotor mode or motor mode MUST be
configured to match the switch settings.
FOCUS SIGNAL=POS
Sets the Focus voltage
output to recall
positional presets
(default).
This is applicable only if the FOCUS SIGNAL=S command is in effect, and the
FOCUS switch is set to the S position (servomotor mode).
Syntax:
SEND_COMMAND CAM,"’FOCUS SIGNAL=POS’"
The command for FOCUS output to servomotor mode or motor mode MUST be
configured to match the switch settings.
FOCUS SIGNAL=S
Sets the Focus output
to be a servomotor
output.
This setting corresponds to the FOCUS switch in the S position.
Syntax:
SEND_COMMAND CAM,"’FOCUS SIGNAL=S’"
The command for FOCUS output to servomotor mode or motor mode MUST be
configured to match the switch settings.
FP
Sets the lens’ Focus
mode to positional
(default).
This command can be used only for servomotor mode.
Syntax:
SEND_COMMAND CAM,"’FP’"
The FP command applies only if you connect pin 6 (zoom), 7 (focus), and/or 9
(iris) to the lens control connector. These pins determine if the lens is in posi-
tional or speed mode.
FS
Sets the lens’ Focus
mode to speed.
This command can be used only for servomotor mode.
Syntax:
SEND_COMMAND CAM,"’FS’"
The FS command applies only if you connect pin 6 (zoom), 7 (focus), and/or 9
(iris) to the lens control connector. These pins determine if the lens is in posi-
tional or speed mode.