Instruction manual
Verifying Signal Status
5
CP-10 Instruction Manual
Verifying Signal Status
Signal status can be verified to confirm that a switch has executed properly or to confirm correct routing 
to multiple outputs (destinations) without accidently executing or disconnecting switches. Input status 
and output status both function on the CP-10 Control Panel. An output can only receive a signal from 
one input (source); therefore verifying the status of an output will display only the one input it is 
currently receiving a signal from. It will not show other outputs that are also receiving a signal from the 
same input. Verifying an input will display all outputs currently receiving the input’s signal. 
Once in Status mode, the CP-10 stays in Status mode until the Cancel Key is pressed. You can return to 
the Command screen at any time by pressing the Cancel Key.
The following example verifies the signal status for Input 2 on Level 0.
To verify the status of an input signal:
1.
At the Command screen, press the Status Key.
The Status screen appears.
2. Press the Level Key and enter “0.”
3. Press the Input Key and enter “2.”
4. Press the Take Key.
A single output – The Status screen below left indicates that Input 2 is routed to Output 4.
Multiple outputs – The Status screen below right indicates that Input 2 is routed to multiple 
outputs. When the screen does not have enough room to display all of the outputs that the input is 
routed to, use the right arrow key to scroll right and see the rest of the outputs.










