Instruction manual
NXB-AP-1000 Interface – Initial Setup by Network Admin
84
Epica DGX 16 and Epica DGX 32 Instruction Manual
Connecting to a NetLinx Master
To establish communication between an Epica DGX 16 or 32 and a NetLinx Master:
1.
From the Admin drop down menu, select Master Connection.
2. Optional – Under Connection Mode, select one of the options (default = TCP/IP URL).
3. Under Mode Settings, enter the Master’s IP/URL in the Master IP/URL text field.
Important: Do not change the default Master Port Number assignment of 1319 (unless the master
has been configured to use a different port).
4. If the NetLinx Master has Authentication enabled – Under Authentication Settings, enter the
Master Username and Master Password.
5. Click Accept to save the changes.
6. Click Reboot to reboot the Epica DGX 16 or 32 connection. Once rebooted, the matrix switcher is in
communication with the NetLinx Master, as indicated by steady a blink on the enclosure’s
NXB-AP-1000 Status LED to the left of the TCP/IP port.
Important: Any time you click “Reboot” from any page in the NXB-AP-1000 interface, the server
reboots. The reboot updates information between the Epica DGX 16 or 32 and the server.
(The Epica DGX 16 or 32 system itself does not reboot).
Note: For information on using NetLinx Studio, see the NetLinx Studio online Help and the
“NetLinx Integrated Controllers WebConsole & Programming Guide” at www.amx.com.
FIG. 45 Master Connection page