Instruction manual
Installation and Setup
43
Instruction Manual – Enova DGX 8/16/32 Digital Media Switchers
The LAN 100/1000 (RJ-45) port is an Ethernet link connector, handling Ethernet 10/100/1000
connections for 1000 Mbps (megabits per second), 100 Mbps, and 10 Mbps. This connection is
compatible with most Ethernet based LANs.
Important: Because the LAN 100/1000 port is the single, shared connection to the LAN for all
connected DXLInk Transmitters and Receivers, if the LAN port on the Transmitters and Receivers
will be used for network connectivity, a Gigabit (1000 Mbps) LAN connection between the network
and the Enova DGX Switcher’s LAN port is strongly recommended. Lower speed connections may
result in inferior performance of the embedded Ethernet network.
The two small rectangular LEDs on the RJ-45 connector indicate the following:
Green L/A LED
On – Link is active (when the Ethernet cable is connected and terminated correctly)
Yellow SPD LED
On – receiving or transmitting LAN data packets
IP Protocols Used by the Integrated Controller
IP Protocols Used by the Integrated Controller
Protocol Description Standard Port #
FTP The integrated Master has a built-in FTP server 21/20 (TCP)
SSH The SSH port functions using the same interface as Telnet but over a
secure shell where it uses SSL as a mechanism to configure and diagnose
a NetLinx system. This port value is used for secure Telnet communication.
Note: Only SSH version 2 is supported.
22 (TCP)
Telnet The NetLinx Telnet server provides a mechanism to configure and
diagnose a NetLinx system.
For maximum flexibility, the Master can be configured to use a different port
than 23 or disable Telnet completely from either Telnet or the Program port
on the rear of the Enova DGX Switcher. Once disabled, the only way to
enable Telnet again is from the Program port.
23 (TCP)
HTTP The integrated Master has a built-in web server that complies with the
HTTP 1.0 specification and supports all of the required features of
HTTP v1.1. This port is used for unsecured HTTP Internet communication
between the web browser’s UI and the integrated Master.
80 (TCP)
HTTPS/
SSL
This port is used by a web browser for secure communication between the
web server UI and the integrated Master. This port is also used for
simultaneous encryption of this data, using the SSL certificate information
on the Master as a key.
443 (TCP)
ICSP The port is used for peer-to-peer protocol for both Master-to-Master and
Master-to-device communications.
For maximum flexibility the Master can be configured to use a different port
than 1319 or disable the ICSP over Ethernet completely from either Telnet
or the Program port on the rear of the Enova DGX Switcher. This type of
communication is used by various AMX products for communication
among themselves (see page 151).
1319 (UDP/TCP)