Instruction manual
NXB-AP-1000 Interface – Initial Setup by Network Admin
80
Epica DGX 32 Instruction Manual
To access the Epica DGX 32 via Zero-Config:
1.
In NetLinx Studio (v3.0 or higher), click in the Zero-Config tab to access the Zero-Config shortcut
menu.
2. Select Refresh Zero-Config List to generate an initial listing of all Zero-Config devices that have
been detected.
3. Click the plus symbol (+) to expand any device in the Zero-config list.
The device’s current IP Address is listed below the device name.
4. Double-click on the NIB IP-Bridge Interface. The matrix switcher’s interface (HTML) is displayed
in a NetLinx Studio window.
Connecting to a NetLinx Master
To establish communication between the Epica DGX 32 and a NetLinx Master:
1.
From the Admin drop down menu, select Master Connection.
2. Optional – Under Connection Mode, select one of the options (the default is TCP/IP URL).
3. Under Mode Settings, enter the Master’s IP/URL in the Master IP/URL text field.
Important: Do not change the default Master Port Number assignment of 1319 (unless the master
has been configured to use a different port).
4. If the NetLinx Master has Authentication enabled – Under Authentication Settings, enter the
Master Username and Master Password.
5. Click Accept to save the changes.
6. Click Reboot to reboot the Epica DGX 32 connection. Once rebooted, the matrix switcher is in
communication with the NetLinx Master, as indicated by steady a blink on the enclosure’s
NXB-AP-1000 LED to the left of the TCP/IP port.
Important: Any time you click “Reboot” from any page in the NXB-AP-1000 Interface, the server
reboots. The reboot updates information between the Epica DGX 32 and the server.
(The Epica DGX 32 system itself does not reboot).
Note: For information on using NetLinx Studio, see the NetLinx Studio online Help and the
“NetLinx Integrated Controllers WebConsole & Programming Guide” at www.amx.com.
FIG. 37 Master Connection page