Instruction manual

Epica DGX 32 SC Optical Boards
49
Epica DGX 32 Instruction Manual
4. Insert the fiber cable connector into the input and output SC fiber receptacles (FIG. 27).
5. Tie the SC fiber cable to the cable management bar far enough below the connector to allow for the
manufacturers recommended bend radius. The bend radius for AMX SC terminated fiber cables is
2 inches (5 cm).
6. Repeat the previous steps for the remaining fiber cables.
Important: The RS-232 connection on the modules requires management of the RS-232 data line in
relation to switching operations. In an upstream matrix switching scenario, we recommend that
RS-232 control commands (via the DGX RS-232 data connection) are not sent immediately prior or
subsequent to a matrix switching command. It is possible for the RS-232 data to be corrupted as the
video (or audio) signal is removed and then restored by the matrix switcher.
FIG. 27 Fasten cables onto input and output connectors (shown with cable management bar)