Instruction manual

Overview and Specifications
21
DGX Transmitters & Receivers Instruction Manual
AMX reserves the right to modify its products and their specifications without notice.
Serial Data Specifications
TX
Input Signal Type Unidirectional RS-232: the control signal is transmitted in the same
direction as video/audio
Video signal must be present to pass serial data
Input Signal Level (max.) +/-15 V
Baud Rate (max.) 115.2 k baud, 25 ft. (7.6 m) copper cable
Baud Rate (typical) 57.6 k baud, 150 ft. (45.7 m) copper cable
Input Connector Pluggable 3.5 mm terminal block
RX
Output Signal Type Unidirectional RS-232: the control signal is transmitted in the same
direction as video/audio
Output Signal Level (max.) +/-5 V
Baud Rate (max.) 115.2 k baud, 25 ft. (7.6 m) copper cable
Baud Rate (typical) 57.6 k baud, 150 ft. (45.7 m) copper cable
Output Connector Pluggable 3.5 mm terminal block