Instruction manual

Network Configuration
72
Instruction Manual – DXLink™ Twisted Pair Transmitters/Receiver
Tip: To monitor the ID Pushbutton boot state of a module, see the “ID Pushbutton Boot and NetLinx LED
Behavior” table below.
ID Pushbutton Boot State and LED Behavior
To monitor the ID Pushbutton boot state of a module by its LEDs, check both the Link/Act and Status LED columns.
ID Pushbutton Boot and NetLinx LED Behavior
ID Pushbutton Boot States Link/Act LED Status LED
Boot with ID Pushbutton held down Slow blink (1 Hz) Slow blink (1 Hz)
ID Pushbutton held down long enough for
reset to default parameters
Fast blink until ID Pushbutton is
released, then OFF
Fast blink until ID Pushbutton is
released, then OFF
ID Pushbutton held down long enough for
reset to default firmware image
Solid ON, transitions to OFF once
the unit completes writing to flash
and is ready to reboot
Solid ON, transitions to OFF once
the unit completes writing to flash
and is ready to reboot
In Auto ID mode Normal Blink (2 Hz)
ID Pushbutton held down long enough to
accept new ID
2 blinks, then normal 2 blinks, then normal
After boot: ID Pushbutton held down, but not
long enough for IP mode change
Slow blink (1 Hz) Slow blink (1 Hz)
After boot: ID Pushbutton held down long
enough for IP mode change
Fast blink, then OFF Fast blink, then OFF