Operator`s manual

Figure 4.3: Ribbon Advance Cable
4.5.16: Ribbon Advance Mechanism Removal and Replacement - Figure 4.4.
1 . Remove top cover (see Paragraph 4.5.1).
2. Remove operator panel (see Paragraph 4.5.3).
3 . Remove ribbon advance cables (see Paragraph 4.5.15).
4. Remove two screws (175) securing ribbon advance mechanism (161) to carriage
(160) and remove mechanism.
5. Replace in reverse order.
6. After installation is complete, move the carriage left-right several times to
make certain the drive blade is advancing counterclockwise.
4-12