User manual

ä
Press the key for the required path number.
Available paths are indicated by keys with the integral LEDs illuminated green. The LED in the selected key will
illuminate red.
The selected path will appear in the alpha display next to the ASSIGN key.
Split Metering
The metering keys will always apply to the currently selected bank.
The bus/tape switch will toggle between displaying the bus send or the tape return on the large meter. These are
displayed starting from track 1 on the left hand side of the console, up to 24 / 36 /48 depending on the desk
frame size. In this respect, the bus/tape metering is independent from the placement of the monitor paths on the
surface.
ä The OPER LEVEL key will light a led at 0dB on all meters to show the operating level of the console.
ä Pressing the FOLL FDR key means that as different layers of paths are called to the large faders, so the
metering will follow these paths.
The lower row of metering keys apply to the small meters only.
ä The DYN key enables all the right hand side of the meters to show any gain reduction for compression
(including DRC) that may be present. It will not show any metering for an expander if it is in the path.
The SEL S.MTR and FOLL KNOB keys only apply to the small meters.
ä
If FOLL KNOB is pressed then the small meters will show the metering for whichever paths are on the
logicators.
ä
Press SEL S.MTR to cycle the small meters around the four layers on the currently selected bank.
ä
Pressing the numbered layer key under each individual meter, will cycle the meter to show layer A, B, SUB A
or SUB B on the currently selected bank.
ä
Pressing the DYN key above each individual meter will select or deselect the dynamics metering on that
path, depending on the state of the global dynamics metering.
ä
When working in Surround, the AUX/MON key will swap the top row of Aux metering to show the Film
outputs.
From the Surround Panel, this top row of meters can also be switched to show the Stem outputs.
ä
Press the STEM key on the Meter section of the Surround Panel to show this, and then using the PREV or NEXT
key to cycle round all available stems.
ä
The AUX key will return the meters to displaying auxes 1-8; the MON key will show the film monitors.
ä
When switching the metering from the Surround Panel, the blank key next to Grp/Aux will light green to
show that auxes are being metered; orange to show stem metering and red to show the Films.
Stems and Film monitoring can only be seen if working in a Surround mode.
Metering Meter Bridge
Issue 4 Page 11:3
-10
0
-20
-60
-40
RIGHTLEFT
POWER
SOLO FAIL O/LOAD
0
-10
-5
/
O
-40
-30
-20
-60
-10
0
-20
-60
-40
-10
0
-20
-60
-40
-10
0
-20
-60
-40
-10
0
-20
-60
-40
-10
0
-20
-60
-40
-10
0
-20
-60
-40
-10
0
-20
-60
-40
-10
0
-20
-60
-40
AUX8AUX7AUX6AUX5AUX4AUX2AUX1 AUX3
-10
0
-20
-60
-40
-10
0
-20
-60
-40
-10
0
-20
-60
-40
-10
0
-20
-60
-40
-10
0
-20
-60
-40
-10
0
-20
-60
-40
-10
0
-20
-60
-40
GP8
AUX16
GP7
AUX15
GP6
AUX14
GP5
AUX13
GP4
AUX12
GP3
AUX11
GP2
AUX10
GP1
AUX9
0
+1
VU
-3
80
-2
-7
-5
V
U
-1
3
+
100
20
4
0
-2
0
R22AF
-10
+2
60
0
+1
VU
-3
80
-2
-7
-5
V
U
-1
3
+
100
20
40
-2
0
R22AF
-10
+2
60
ASSIGN
ASSIGN
OPER
LEVEL
FOLL
FDR
BUS/
TAPE
GP/
AUX
AUX/
MON
DYN
SEL
S.MTR
FOLL
KNOB
STRIP METERS