User manual
Control Room Monitoring
The CONTROL ROOM Panel is used to control the output to the main monitoring speakers and the two pairs of
small speaker outputs, Small L/S 1 and Small L/S 2.
The SELECT Panel is always assigned to selecting a control room monitor source, unless a SELECT key on
another panel is pressed and held.
ä
To select a source for the control room Press the MAIN, GRP, AUX, CUE or EXT key on the SELECT Panel.
The integral LED will illuminate red.
ä
Press the key for the required path number.
Available paths are indicated by keys with the integral LEDs illuminated green. The LED in the selected key will
illuminate red and the selected path will appear in the alpha display on the CONTROL ROOM Panel.
Source selection for the control room is interlocked (i.e. the previous source will be de-selected automatically).
See Solo (in this chapter) for information on the operation of the PFL key.
ä
To control the analogue output levels to the speakers, rotate the LARGE LS, SMALL L/S 1 and SMALL L/S 2 to
the required setting.
ä
To switch the control room source to the first or second set of small loudspeakers press the SMALL L/S 1 or
SMALL L/S 2 key as required.
The integral LED will illuminate orange and the main speakers will be cut and the control room monitoring
source will be sent to the small loudspeakers.
If SMALL L/S 1 and SMALL L/S2 are active at the same time then the source will be sent to SMALL L/S 2 only.
Monitoring Control Room Monitoring
Issue 4 Page 8:2
SELECT*
MAIN GRP
15
13
11
9
7
5
3
1
16
14
12
10
8
6
4
2
PFL
AUX
EXT
CUE
SURROUND
MAIN
LARGE LS
CONTROL
ROOM
MONO
SOLO
CLEAR
M/S
PHASE
RIGHT
PHASE
LEFT
SMALL
L/S 2
SMALL
L/S 1
CUT
DIM
CUT
LEFT
CAL
CUT
RIGHT
-3
-6
USER