User manual
Options Menu
Glide Times
Allows users to adjust Glide rates for Match and Auto Match mode. Glide times can be changed at any time
(including during the running of automation).
Because a Glide is written into the fader data, any change in Glide Time settings does not affect previously
written Glides.
ä
To set glide times click on Glide Times in the drop down Options menu or click on the Glide Times area in the
main screen.
The Glide Times dialogue box will appear.
ä
Adjust the times as required by either using the horizontal scroll bars or entering the desired number into the
Frame boxes via the keyboard and click on OK to close the Dialogue box.
Safety Nets
Used to set up a window (between two points in timecode) inside which new automation Events can be
recorded. For instance, in post production the Safety Nets can be used to safeguard the automation in the
regions either side of a scene and automatically record new automation during the scene.
The Safe Before and Safe After times can be set manually or from the Label List.
Controls can be placed into a pending record mode in advance of the Safe Before time using any automation
Record Mode, including Master Touch Record in Collect Touch. At the Safe Before time the system will
immediately transition the controls into recording new automation and drop out of record at the Safe After time
to return to the previous automation pass settings.
The Encore screen displays countdown wipes which start 5 seconds before the Safe Before and Safe After times.
ä
To set safety nets click on Set Safety Net Times in the drop down Options Menu.
The Safety Nets dialogue box will be displayed.
ä
Enter the Safe Before and Safe After times either manually or by clicking in the Label List below each time.
Click on Activate Safety Nets check box so that an X is shown in the box and click on OK to return to the main
screen.
The Safety Net Status Line under the Label List on the main screen will show the safety net times.
If an automation pass is stopped before the Safety Net End time is reached then the control positions will match
to the Play Pass Position at the Safety Net End time.
Options Menu Glide Times