Service manual

Reset and Services
Reset
Reset occurs
(a) at power-up
(b) from the reset switch on the SPS Control Card
(c) clicking the Reset button in the Service Control program (available in the Encore
program group)
(d) clicking the Reset button in the Desk Explorer program (available in the Encore
program group)
Reset propagation may be checked using the red RST LEDS on each card: the link topology
drawings show the propagation of reset through the system.
When a transputer receives a reset signal it assumes the data that follows is its program
which it automatically executes. If a link has not been correctly terminated, noise at the
differential input may cause incorrect program data to be received and subsequent boot
failure. This condition is identified by activity on any of the four green link LEDS immediately
after receiving a reset signal. Any such activity must by corrected by ensuring the correct
termination plugs are present and that all parts of the system are powered up.
Services
Reset is just one of three “services” connections: the other two are “Analyze” and “Error”.
The Error signal propagates “up” through the hierarchy notifying higher level transputers of
faults on the sub-system, whereas Analyze and Reset flow “down”. Analyze is used during
system development to halt transputer operation while preserving current status
information. Four services connections are provided on each card, each consisting of Reset,
Analyze, and Error (RAE). Logic on the card provides one “up” service channel and three
“down” channels which normally parallel the links, although there are exceptions.
Digital Service Manual