Service manual
Record Tally (Opto-isolated Reader Inputs)
Location: Rear of Recorder Interface Unit
Mating connector required: 50-way D type male
Tallies must be connected via a resistor of appropriate value to limit current to less than
10mA, e.g. if tally signal from machine is active high 5V it would be connected to the + PIN
via a 470 ohm resistor. Typical connection schemes:
1-24
+-
25-48
+-
PIN PIN PIN PIN
Record Tally 1 2 3 Record Tally 25 2 3
Record Tally 2 4 5 Record Tally 26 4 5
Record Tally 3 6 7 Record Tally 27 6 7
Record Tally 4 8 9 Record Tally 28 8 9
Record Tally 5 10 11 Record Tally 29 10 11
Record Tally 6 12 13 Record Tally 30 12 13
Record Tally 7 14 15 Record Tally 31 14 15
Record Tally 8 16 17 Record Tally 32 16 17
Record Tally 9 18 19 Record Tally 33 18 19
Record Tally 10 20 21 Record Tally 34 20 21
Record Tally 11 22 23 Record Tally 35 22 23
Record Tally 12 24 25 Record Tally 36 24 25
Record Tally 13 26 27 Record Tally 37 26 27
Record Tally 14 28 29 Record Tally 38 28 29
Record Tally 15 30 31 Record Tally 39 30 31
Record Tally 16 32 33 Record Tally 40 32 33
Record Tally 17 34 35 Record Tally 41 34 35
Record Tally 18 36 37 Record Tally 42 36 37
Record Tally 19 38 39 Record Tally 43 38 39
Record Tally 20 40 41 Record Tally 44 40 41
Record Tally 21 42 43 Record Tally 45 42 43
Record Tally 22 44 45 Record Tally 46 44 45
Record Tally 23 46 47 Record Tally 47 46 47
Record Tally 24 48 49 Record Tally 48 48 49
Digital Service Manual
Issue 3 Page 57
+
-
Opto-isolated inputs
Rated at 10mA
VDC
R 10mA
28 VDC
R
2.7K ohms
5VDC
R
47
0o
hm
s
MAGNATECH
DUBBER
MULTITRACK