Dubber Tally (Opto-isolated Reader Inputs)
Location: Rear of Recorder Interface Unit
Mating connector required: 50-way D type male
Tallies must be connected via a resistor of appropriate value to limit current to less than
10mA, e.g. if tally signal from machine is active high 5V it would be connected to the + PIN
via a 470 ohm resistor. Typical connection schemes:
1-24
+-
25-48
+-
PIN PIN PIN PIN
Dubber Tally 1 2 3 Dubber Tally 25 2 3
Dubber Tally 2 4 5 Dubber Tally 26 4 5
Dubber Tally 3 6 7 Dubber Tally 27 6 7
Dubber Tally 4 8 9 Dubber Tally 28 8 9
Dubber Tally 5 10 11 Dubber Tally 29 10 11
Dubber Tally 6 12 13 Dubber Tally 30 12 13
Dubber Tally 7 14 15 Dubber Tally 31 14 15
Dubber Tally 8 16 17 Dubber Tally 32 16 17
Dubber Tally 9 18 19 Dubber Tally 33 18 19
Dubber Tally 10 20 21 Dubber Tally 34 20 21
Dubber Tally 11 22 23 Dubber Tally 35 22 23
Dubber Tally 12 24 25 Dubber Tally 36 24 25
Dubber Tally 13 26 27 Dubber Tally 37 26 27
Dubber Tally 14 28 29 Dubber Tally 38 28 29
Dubber Tally 15 30 31 Dubber Tally 39 30 31
Dubber Tally 16 32 33 Dubber Tally 40 32 33
Dubber Tally 17 34 35 Dubber Tally 41 34 35
Dubber Tally 18 36 37 Dubber Tally 42 36 37
Dubber Tally 19 38 39 Dubber Tally 43 38 39
Dubber Tally 20 40 41 Dubber Tally 44 40 41
Dubber Tally 21 42 43 Dubber Tally 45 42 43
Dubber Tally 22 44 45 Dubber Tally 46 44 45
Dubber Tally 23 46 47 Dubber Tally 47 46 47
Dubber Tally 24 48 49 Dubber Tally 48 48 49
Digital Service Manual
Issue 3 Page 56
+
-
Opto-isolated inputs
Rated at 10mA
VDC
R 10mA
28 VDC
R
2.7K ohms
5VDC
R
47
0o
hm
s
MAGNATECH
DUBBER