Service manual
As the system is being reset the user must also observe the link LEDS on each transputer
card. None of these LEDS should flash at the point the cards are being reset.
The Link Topology indicates how the link network is constructed. On the transputer network
link 0 is always the input to the transputer and link 1, 2 or 3 are outputs. Therefore, link 0 of a
particular transputer is usually connected to link 1 of the previous transputer in the chain.
If link activity on reset is observed on the first transputer in a cardframe then, as earlier with
the reset path, this can be caused by either the Tranlink cable that connects both card frames
or possibly the internal link cables that are involved.
Once the user has established that the system has good PSUs a good continuous reset path
and no link activity on any of the transputer cards upon reset we can progress onto the main
boot sequence.
Encore Boot Sequence
When the Encore Processor unit is powering up or re-booting, the left hand LCD screen (on
24 and 48 fader systems) will display status messages.
The graphics adaptor card will display its BIOS information.
A CPU and memory check message will be displayed if the system is performing a cold boot.
The system BIOS version will be displayed.
The SCSI controller card will boot and display its BIOS version.
The SCSI controller card will perform a self test and determine which devices are attached to
it.
The system will boot the operating system from the first bootable hard disk.
The system is now under the control of the Microsoft Windows NT boot loader.
A menu will be displayed for operating system version selection. Either press Enter or allow
the system to time out and select the default.
Microsoft Windows NT will now boot.
ä
Log into the system with an appropriated user name.
-
See the User Manual for further information on logging into Encore.
ä
Double click on the AMS Neve Encore program group icon.
A window will open containing icons representing the Encore programs.
If the console system boot has been completed Encore may be started.
Encore is launched by double clicking on the Encore icon.
The main Encore screen will be displayed.
Digital Service Manual