Installation manual

Mains Power
The console is DC powered and requires a bulk PSU to be fitted in a machine room. This unit
holds two hot-swap modules each of which has an independant mains feed which gives full
redundancy.
Typical power consumption given below is based on fully populated racks.
Check that the voltage selector on the rear of the Encore Processor Rack, Relay Control Unit and
Remote 8 Channel Level Control Unit is set to the correct operating voltage. All other rack units
are auto voltage sensing.
The input voltage range and fuse rating are engraved on the equipment label adjacent to the
mains input connector.
Power Requirements
Console Power Consumption (Watts)
12 Fader Console 320
24 Fader Console 490
36 Fader Console 660
48 Fader Console 830
Meter Bridge 100
System Racks Power Consumption (Watts)
Encore Processor Rack 100
SPS Rack (17U) 800
MIOS Rack 150
Relay Control Unit 20
Remote 8Ch Level Control Unit 20
Multichannel AES I/O Unit 60
Console Data Refer to the drawings at the back of this manual.
Rack Data
Rack Type U Depth
mm (inches)
Height
mm (inches)
Approx. Weight
kg (lbs)
Console PSU 2 351 (14) 89 (3½) 13 (29)
Encore Processor 4 460 (18) 178 (7) 30 (66)
System SPS Rack 17 572 (22½) 756 (29¾) 70 (154)
MIOS Rack 4 490 (19) 178 (7) 21 (46) *
Relay Control Unit 2 254 (10) 89 (3½) 8 (18)
Remote 8Ch Level Control Unit 2 254 (10) 89 (3½) 8 (18)
Multichannel AES I/O Unit 2 425 (17) 89 (3½) 9 (20)
* The weight of the MIOS rack is based on a rack populated with 6 mic modules.
Logic MMC Installation Manual
Issue 5 Page 5