User's Manual
DP3010R VIDEO DOOR PHONE
63
Press “#” to unlock
by
You can select the timer “Immediately”, ”One Second”, or ”Two Second”.
Press the “#” key from IP Video Phone/Video Indoor Station to open “Electronic Door Lock”
during answering the call.
Unlock by RFID
Password
There are two options:
Disable: Disable the function of using RFID Password to open Electronic Door Lock.
RFID Password: Enter RFID password to open “Electronic Door Lock”.
Trigger By Digit
Input 2
You can set the “Digit Input 2(DI2)” as a trigger point. You may select the voltage polar “Low
(High->Low)”to “High (Low->High), or “Disable” for triggering.
NOTE: The DI2 (Digit Input 2) is used to connect Door Open Button.
It depends on the types (open, short circuit) of Door Open Button to select “Low
(High->Low)”or “High (Low->High).
Ethernet Some trusted Ethernets can be set up as a trigger point. Please contact with the provider
when you need more information. Or, you may disable this function.
Save Click this button to save your setting.
NOTE: Be careful with the wires connection of GPIO, especially the default polar voltage of hardware (digit output pins) is
high. Please select and set the related Electronic circuit to meet the hardware initial voltage.