User's Manual

MANUAL FOR SYSTEM INTEGRATOR
16
Step 1 Put wall mounting box into wall hole, place a spirit level (bubble level) on the wall mounting box, mark the
four on the wall for drilling holes.
Step 2 Drill four holes for wall screw anchors.
Step 3 Hammer four wall screw anchors into the drilled holes
(Refer to the figure on next page).
Step 4 Remove L-Iron from wall mounting box by loosing screws.
Step 5 Secure four screws and washers to secure the wall
mounting box and secure four screws on L-Irons.
Step 6 Tie four cable ties on the wall mounting box. (Refer to the
diagram on previous page).
Step 7 Again put wall mounting box into wall hole, secure wall
mounting box with L-Irons by securing four screws.
Step 8 Put Hang Rod in the cable ties, tie Hang Rods tightly on
Wall Mounting Box to keep wall mounting box parallel to
the surface of the wall.
Step 9 Again place a spirit level (bubble level) on the wall mounting box, Fasten L-Irons on the wall.
Step 10 Fasten screws to fasten wall mounting box with L-Irons.
Figure 12: Four Marks and Bubble Level