Care Unit Function
Scene scenario The patient can ask the help from the nurses by pressing the door bell button in the care unit .While the meantime
the DO4 will receive the turn on signal, if there is a external emergency light on the entrance of the unit in order to notify nurses
around.
To turn off the emergency light by set off the DO4 via DI4. If the nurses are not able to be in the care unit immediately then the nurses
can answer the phone first to see the situation of the patient before some one reach them. The light and the urgent light on the
videophone will not be turning off until someone notice. The restart DI4 to turn off the light and other functions
Web UI setting (DO4) DI3 is selected in the DO4 or select “Door
Bell" function
Digit Output 4 will transmit the Polar Reverse according from
setting to notify the external warning light
Functional description
To trigger DO4 to call the intercom in the nurse station
1. By pressing the button of the intercom to call the nurses
2. Pressing DI3 (emergency button)
To set up/off DI4 or disable the function of the external warning
light