Specifications
12 13
• Continuity buzzer
• Hold and maximum reading functions
• Auto ranging
• Auto power off and low battery indication
• Rubber over-molded case
• Frequency is measured by either jaws or
test leads (ACD-10 PLUS/ACD-10
TRMS-PLUS only)
• Microamps measurement for testing
flame sensors (ACD-14 PLUS and
ACD-14 TRMS-PLUS only)
• Diode test (ACD 14 PLUS and
ACD-14 TRMS only)
• True-rms for more accurate readings in
noisy measurement environments (ACD-10
TRMS-PLUS and ACD-14-TRMS-PLUS only)
N10140
Clamp Multimeters – Extend basic clamp capabilities with multimeter functions for full troubleshooting power
ACD-10 PLUS and ACD-10 TRMS-PLUS
Clamp Multimeters with Unique Thin Jaws
ACD-14 PLUS and ACD-14 TRMS-PLUS
Dual Display Digital Clamp Multimeters
With thinner jaws than standard clamp multimeters (only 0.4”/10 mm thick),
the ACD-10 PLUS, ACD-10 TRMS-PLUS, ACD-14 PLUS, and ACD-14 TRMS PLUS
allow access to tight measurement areas and still accommodate conductors
up to 1 inch (25 cm).
The ACD-14 PLUS and ACD-14 TRMS-PLUS are the professional’s choice for
both HVAC and electrical applications with a complete set of measurement
features including dual displays that allow you to view amperage and
voltage measurements simultaneously.
INCLUDED ACCESSORIES: Test leads, battery (installed),
soft carrying pouch, type-K thermocouple with banana plug
(ACD-14 PLUS and ACD-14 TRMS-PLUS only), users manual
FEATURES ACD-14 PLUS ACD-14 TRMS-PLUS ACD-10 PLUS ACD-10 TRMS-PLUS
True-rms
–
•
–
•
AC Voltage
4.000 V, 40.00 V, 400.0 V, 600 V
DC Voltage
400.0 mV, 4.000 V, 40.00 V, 400.0 V, 600 V
AC Current
40.00 A, 400.0 A, 600 A
Resistance
400.0
Ω
, 4.000 k
Ω
, 40.00 k
Ω
, 400.0 k
Ω
, 4.000 M
Ω
, 40.00 M
Ω
Capacitance
500.0 nF, 5.000 µF, 50.00 µF, 500.0 µF, 3000 µF
Frequency
40 Hz
^
400 Hz with Jaw, 10 Hz
^
100 kHz with test leads
Temperature
-4 °F
^
999 °F (-20 °C
^
537 °C) – –
Dual Displays
• •
– –
Micro Amps
• •
– –
Accommodates
Conductors
up to 1.0” (25 mm) in diameter
N10140
• Automatic selection of ac volts, dc volts or
ac amps
• Total Harmonic Distortion to 51st harmonic
(ACD-41PQ)
• Dual-display power factor readout with
KWh recording (ACD-45PQ)
• Ultra slim jaws clamp around conductors
in confined and difficult-to-reach-places
• Large easy-to-read LCD with backlight
• Automatic polarity
• Audible continuity
• Auto power-off
• Low battery indication
• Peak hold
• Data hold
• Optional PC communication capabilities
with USB-KIT2
Safety and performance for industrial, utility or outdoor environments
– CAT IV Industrial Clamp Meters
ACD-41PQ 1000A Power Quality Clamp
ACD-45PQ Compact Power Quality Clamp
The ACD-41PQ provides a simple and effective way to verify if the electrical
systems are affected by harmonics with power analysis functions to enhance
troubleshooting. The compact ACD-45PQ measures energy and power on
single and three-phase systems (balanced and unbalanced).
INCLUDED ACCESSORIES: Carrying case, test leads, batteries (installed),
type-K thermocouple, users manual
ACD-41PQ
1000A CLAMP-ON POWER
QUALITY METER W/THD-F
ACD-45PQ
600A POWER QUALITY CLAMP
RS-1007 PRO
CLAMP METER ANALOG CAT IV
600V-1000A, 2 INCH JAW
RS-3 PRO
CLAMP METER ANALOG CAT IV
600V-300A, 1 INCH JAW
FEATURE ACD-41PQ ACD-45PQ
True-rms
•
AC Current
40.00 A, 400.0 A, 1000 A 40.00 A, 400.0 A, 600 A
AC/DC Voltage
600.0 V
Resistance
999.9
Ω
Continuity
•
Temperature
-58 ˚F
^
572 ˚F (-50 ˚C
^
300 ˚C) -
Frequency
5.00 Hz
^
500.0 Hz
Active Power (W)
0 kW
^
600.0 kW 0 kW
^
360.0 kW
Reactive Power (VAR)
0 kVAR
^
600.0 kVAR 0 kVAR
^
360.0 kVAR
Apparent Power (VA)
0 kVA
^
600.0 kVA 0 kVA
^
360.0 kVA
Power Factor
0.10
^
0.99
Energy (KWHr)
–
•
Total Harmonic Distortion (THD%)
0.0 %
^
99 % –
Accommodates Conductors
up to 1.77” (45 mm) in diameter up to 1.02” (26 mm) in diameter
RECOMMENDED ACCESSORIES
DL248D Deluxe Test Leads Kit
(See Page 76)
ELS2A AC Line Splitter
(See Page 18)
RECOMMENDED ACCESSORIES
DL248D Deluxe Test Leads Kit
(See Page 76)
ELS2A AC Line Splitter
(See Page 18)
USB-KIT2 PC software and
connection kit
(See Page 79)
RS-3/RS-1007 PRO CAT IV Analog Clamp Meter
Take these clamp meters to extremes. Digital clamp meters have LCD screens
that tend to freeze below 32 ºF (0 ˚C) but the Amprobe analog clamp meters
can take extreme heat or cold and keep on measuring amps and volts–
without problems or batteries.
• Easy-to-read rotary scale
• Works in temperatures from 5º to 122ºF
• Does not need batteries to measure volts
or amps
• Operates on 50 and 60Hz frequencies
• Pointer lock - data hold
FEATURE RS-3 PRO RS-1007 PRO
AC Voltage
150 V, 300 V, 600 V
AC Current
6 A, 15 A, 40 A, 100 A, 300 A 15 A, 40 A, 100 A, 300 A, 1000 A
Resistance
1000
Ω
Continuity
•
Accommodates Conductors
up to 1.64” (41 mm) in diameter up to 1.88” (47 mm) in diameter
INCLUDED ACCESSORIES: Test leads, battery (installed, for resistance
measurement only), users manual, carrying case
N10140
Clamp Meters
Clamp Meters
ORDERING INFORMATION
For detailed specifications
go to www.Amprobe.com
ORDERING INFORMATION
For detailed specifications
go to www.Amprobe.com
ACD-10 PLUS
DIGITAL CLAMP ON METER, CAP,
FREQ
ACD-10 TRMS-PLUS
DIGITAL CLAMP ON METER, TRUE
RMS, CAP, FREQ
ACD-14 PLUS
DUAL DISPLAY DIGITAL CLAMP-ON
MULTIMETER
ACD-14 TRMS-PLUS
DUAL DISPLAY DIGITAL CLAMP-ON
MULTIMETER, TRMS
RECOMMENDED ACCESSORIES
DL248D Deluxe Test Leads Kit
(See Page 76)