Specifications

62 63
HVAC / Environmental
INCLUDED ACCESSORIES: Users manual, batteries (installed)
INCLUDED ACCESSORIES: 2 x 500 ml plastic beakers, spirit (alcohol), glass thermometer,
battery installed), carrying case, users manual
TX900 Microwave Leak Detector
For domestic and commercial appliance engineers who service microwave ovens,
the TX900 verifies if the oven operates in accordance with current standards and
regulations.
• Measures for wave leakage and tests oven power
• 8 dipole sensors to detect plane wave signals of any polarization
• Temperature compensation for accurate readings regardless of ambient temperature changes
• Analog Bar Graph
• Compact, ergonomic design
• Low battery indicator
• Auto-zero
Gas Leak Detectors – Keep environments safe
CM-100 Carbon Monoxide Meter
This compact meter measures the presence of CO and warns you when it
exceeds safe levels.
• Alarm is preset to 25 ppm to warn about
possible danger
• Adjustable CO warning levels: 25, 30, 35,
45, 50, 70, 100 and 200 ppm
• Backlight for viewing in dim areas
• Auto power-off to save batteries
• Self-test feature
• Dual digital backlit display
TX900
MICROWAVE LEAKAGE
DETECTOR KIT
ULD-300
ULTRASONIC LEAK DETECTOR
TMULD-300
ULTRASONIC LEAK DETECTOR
with TRANSMITTER
FEATURE TX900
RF Power Sensing Range
0 mW/cm
2
^
10 mW/cm
2
Nominal Detecting Frequency
2.45 GHz
FEATURE CM-100
Range
0 ppm
^
999 ppm
Resolution
1 ppm
HVAC / Environmental
Keep environment safe – Gas Leak Detectors
CM-100
CARBON MONOXIDE METER
W/ADJUSTABLE CO LEVELS
CO2-100
CO2 METER
CO2-200
CO2 MOUNTABLE METER
INCLUDED ACCESSORIES: Batteries (installed), users manual, carrying case
INCLUDED ACCESSORIES: Batteries (installed), carrying case, power adapter 110-240 V AC, users manual
CO2-200 Wall-Mounted CO
2
Meter
Monitor critical, environmentally controlled areas such as laboratories and
production facilities with this permanently mounted air quality meter.
• CO
2
measurements up to 9,999 ppm,
temperature, relative humidity, dew point
and wet bulb
• Audible alarm threshold setting for carbon
dioxide levels with output drive relay to
control air flow system
• High performance low drift sensor designed
with NDIR (Non-Dispersive Infrared) wave
guide technology with automatic back
ground calibration
• Recording of min, max and average values
with recall function
• Data hold
CO2-100 Handheld CO
2
Meter
Get instant feedback on CO
2
levels up to 9,999 ppm, while you check the air
quality compliance of hospitals, schools, offices, or production floors.
• Large, easy-to-read triple LCD display of CO
2
, temperature and relative humidity
• Selectable display of dew point and wet bulb
• High performance low-drift sensor designed with NDIR
(Non-Dispersive Infrared) waveguide technology
• Backlight for working in dim areas
• TWA (time-weighted average) display for an 8-hour period
• 15 minutes STEL (short-term exposure limit) value
• Audible alarm threshold setting by carbon dioxide level
• Data hold, min/max, average functions
• Long term drift compensation for accurate readings
FEATURE CO2-100 CO2-200
C02
0
^
9999 ppm 0
^
9999 ppm
Temp. Range
14 °F
^
140°F (-10 °C
^
60 °C ) 14 °F
^
140 °F (-10 °C
^
60 °C)
RH Range
0 %
^
95 % 0 %
^
95 %
DP (Dew Point Temp.)
-4 °F
^
139.8 °F (-20 °C
^
59.9 °C) -4 °F
^
139.8 °F (-20 °C
^
59.9 °C)
WB (Wet Bulb Temp.)
24.8 °F
^
139.8 °F (-5.0 °C
^
59.9 °C) 23 °F
^
139.8 °F (-5.0 °C
^
59.9 °C)
Resolution
1 ppm - CO
2
concentration,
0.1 °C / °F - Temp, 0.1 %RH - Humidity
1 ppm - CO
2
concentration,
0.1 °C / °F - Temp, 0.1 %RH - Humidity
ORDERING INFORMATION
For detailed specifications
go to www.Amprobe.com
ORDERING INFORMATION
For detailed specifications
go to www.Amprobe.com
N10140
N10140
N10140
N10140
Ultrasonic Leak Detectors
When leaks occur in pressurized systems, they emit an ultrasonic frequency
humans can’t hear. These ultrasonic leak detectors convert the sounds into an
audible range for fast, easy leak detection.
ULD-300 Ultrasonic Leak Detector
Quickly locate gas leaks in pressurized air lines, steam lines, and refrigeration
systems regardless of gas type (CFC, HFC, nitrogen and other non-combustible
gases).
• Locates arcing in an electrical system
• Finds the ends of buried PVC pipes
• Parabola shield reduces background noise
• Access difficult or dangerous areas with
extension tube
INCLUDED ACCESSORIES: Flexible tubing adapter, tubular extension, carrying case,
power parabola, headphone, batteries (installed)
N10140
TMULD-300 ULD-300
RECOMMENDED ACCESSORIES
UT300
Ultrasonic Transmitter
(ULD-300)
TMULD-300 Ultrasonic Leak Detector with
Ultrasonic Transmitter
When leaking gases are not sufficiently pressurized, use the TMULD-300. It
includes an ultrasonic transmitter that creates sound waves so you can check
door or trunk seals for air tightness, or windshields for water tightness.
• Same features as ULD-300
• Transmitter “pressurizes” an area with ultrasonic sound
INCLUDED ACCESSORIES: Flexible tubing adapter, tubular extension, carrying case,
power parabola, headphone, batteries (installed), UT-300 transmitter
N10140