Specifications
60 61
RECOMMENDED ACCESSORIES
RLD-1 SENSOR Replacement
Sensor
RECOMMENDED ACCESSORIES
TM-SWA USB Download Cable
and Software CD
(See Page 79)
HVAC / Environmental
N10140
N10140
FUNCTION RANGE RESOLUTION ACCURACY
Air Velocity
0.4 m/s
^
32 m/s 0.1 m/s +/- 3 %
Air Volume
.0
^
99999 (cfm/cmm) 0.1 CMM - 1 CFM +/- 3 %
Temperature
-4 °F
^
158 °F (-20 °C
^
70 °C)
0.1 °F (0.1 °C) +/- 0.6 %
Relative Humidity
0
^
100 % 0.1 % +/- 3 % @ 77 ˚F (25 °C)
FEATURE TMA-20HW TMA-21HW BEST ACCURACY
Air Flow
0.10 m/s
^
30.00 m/s
0.2 km/hr
^
110.0 km/hr
10 ft/min
^
6000 ft/min
0.10 knots
^
59.0 knots
0.12 MPH
^
68.00 MPH
+/- 3 % of rdg +/-1 %FS
Air Flow Volume
0.000 CFM
^
999900 CFM
0.000 CFM
^
999900 CMM
+/- 3 %
Temperature
-
- 4 °F
^
140 °F
(-20 °C
^
60 °C)
+/- 0.9 °F (+/- 0.5 °C,)
Relative Humidity
- 0.0
^
100 % +/- 3 %
Data Logging and USB Interface
-
•
-
Wet bulb/Dew Point
-
•
-
Anemometers – Air flow simplicity and science
TMA40-A Anemometer,
Relative Humidity and Temperature
With one tool, you can measure air velocity (FPM) or air volume (CFM),
relative humidity, and temperature. Large digital display with backlight
and flexible measurement vane makes measuring easier in difficult areas.
Measures up to 99 points and logs up to 2,400.
• Flexible measurement vane for accessing
difficult areas
• Measures air velocity (fpm), air volume
(cfm), relative humidy, and temperature
• Measure multiple points up to 99
• Data logging up to 2400 data points
• Optional PC interface for charting or analysis
• Large digital display with backlight
TMA-20HW, TMA-21HW Hot Wire Anemometers
Hot wire anemometer technology eliminates bearings and rotating parts to
make these meters durable and measurements stable and accurate. It’s the
simple, safe way to monitor indoor air quality and measure air flow and
temperature in residential, commercial and industrial air conditioning systems.
• Four-foot telescopic wand - no ladder
needed for most commercial applications
• Measures air flow volume in CFM, CMM
• Instant average, 2/3 Vmax flow
measurements
• Velocity m/s, ft/min, knots, km/hr, mph.
• Relative humidity and temperature
measurement (TMA-21HW only)
• Data hold, min/max with time stamp
• Data memory and real-time function
(99 sets)
• 512KB auto data-logging capacity
(TMA-21HW)
• USB interface (TMA-21 only)
• Wet bulb and dew point
• Large backlight LCD display shows five
parameters
TMA40-A
ANEMOMETER, TEMPERATURE,
RH TESTER
TMA-20HW
HOT WIRE ANEMOMETER
TMA-21HW
HOT WIRE ANEMOMETER
INCLUDED ACCESSORIES: Batteries (installed), hard carrying case, users manual,
USB cable and PC software (TMA-21HW only)
INCLUDED ACCESSORIES: Carrying case, battery (installed), users manual,
optional PC interface for charting or analysis
HVAC / Environmental
Keep environments safe – Gas Leak Detectors
INCLUDED ACCESSORIES: Battery (installed), carrying case, users manual
FEATURE RANGE
Methane 40 ppm
^
640 ppm
Propane 35 ppm
^
580 ppm
Sensitivity 35 ppm (propane)
GSD600 Gas Leak Detector
Detect dangerous methane or propane leaks that can lead to explosions and
gas poisoning. With its five-level LED and audible alarms, the GSD600 helps you
assess whether the area is safe or needs to be vented. The frequency of the
beeping increases with the concentration of the gas, allowing you to pinpoint
the source of the leak in piping or appliances. The display provides an accurate
measurement of the gas present in the area.
• Detects combustible gases
• Quickly identifies and pinpoints gas leaks
for closed piping systems
• Automatic calibration feature
• 5 level LED alarm: >40, >80, >160, >320,
and >640 ppm
• Mute function and LED alerts for quiet areas
• Built-in earphone jack (earphone not
included) for loud envirorments
• Flexible probe to access difficult
measurement areas
• Auto power-off
N10140
RLD-1 Refrigerant Leak Detector
Troubleshoot air conditioning systems quickly and accurately with the RLD-1.
State-of-the-art technology makes it easy to precisely pinpoint a wide variety
of halogenated refrigerant leaks.
• Detects R-134a, R-404a, R-407c, R-410a, R-22, Freon and
other refrigerants
• Sensitive gas sensor and advanced digital signal processing
for high accuracy
• Built-in suction pump for precise sensor response
• Tri-color LED display and audio clearly indicate leaks
• High-Medium-Low (H/M/L) leak sensitivity selector
• Automatic zero and background compensation
• Low battery indication
• Ambient concentration reset
INCLUDED ACCESSORIES: Batteries (installed), users manual, carrying case,
leak check bottle, AC adapter
RLD-1
REFRIGERANT LEAK DETECTOR
GSD600
GAS LEAK DETECTOR FOR
METHANE AND PROPANE
FEATURE RFD-1
Detectable Gases
R-134a, R-404A, R-407C, R-410A, R-22, Freon
R-22, 134a Sensitivity
H - 3g/year, M - 15g/year, L - 30g/year
R-404A, 407C, 410A Sensitivity
H - 4g/year, M - 20g/year, L - 40g/year
Alarm Method
Buzzer, Tricolor LED bar Indicator
Power Usage
2 C size (3V DC) Alkaline Batteries
Snake Tube Length
15.5” (40 cm)
NEW
NEW
ORDERING INFORMATION
For detailed specifications
go to www.Amprobe.com
ORDERING INFORMATION
For detailed specifications
go to www.Amprobe.com
N10140