Specifications
Chapter 2 Product Overview
20 Reference Manual ReadyBoard 800
Environmental Specifications
Table 2-11 provides the most efficient operating and storage condition ranges required for this board.
Table 2-11. Environmental Requirements
Processor
600 MHz ULV
Celeron M Conditions
1.0 GHz ULV
Celeron M Conditions
1.4 GHz LV
Pentium M Conditions
Operating
+0° to + 60° C
(32° to + 140° F)
+0° to + 60° C
(32° to + 140° F)
+0° to + 60° C
(32° to + 140° F)
Temperature
Storage –20° to +75° C
(–4° to +167° F)
–20° to +75° C
(–4° to +167° F)
–20° to +75° C
(–4° to +167° F)
Operating 5% to 95%
relative humidity, non-
condensing
5% to 95%
relative humidity,
non-condensing
5% to 95%
relative humidity,
non-condensing
Humidity
Non-
operating
5% to 95%
relative humidity, non-
condensing
5% to 95%
relative humidity, non-
condensing
5% to 95%
relative humidity, non-
condensing
Thermal/Cooling Requirements
The CPU, Northbridge, Southbridge, Secondary I/O, and voltage regulators are the sources of heat
on the board. The ReadyBoard 800 is designed to operate at its maximum CPU speed of 600 MHz,
1.0 GHz, or 1.4 GHz. All processors and the Memory Hub (Northbridge) require a heatsink, but no fan.