8.6 Caution
CAUTION
When removing the sensing head from an operating line, do not assume that the
line is empty or that the isolation or bypass means is working properly. If an
EMC isolation valve is used, be sure its travel is not limited by any external
attachments or other interference and the valve is closed tightly. No pressure should
be felt on the head as the mounting nut is being removed.
ANY PRESSURE FELT WHEN THE NUT IS LOOSENED MUST BE INVESTIGATED
BEFORE PROCEEDING. Steam should be turned off before attempting to remove
head.
Use a face shield and protective clothing. Stand to the side when removing the
sensing head.
Clean all black liquor residue from spud-piece on adapter prior to re-insertion of
sensing head. The o-ring seal should be replaced before re-installation.
CAUTION
Close off isolation valve or remove the sensing head and replace with
maintenance plug prior to steam cleaning process lines to prevent prism
breakage.