Service manual
MDS E-SCAN MONITOR CONFIGURATION STATES SELECTION
46
5.5 Configuration States Selection
The first configuration option, “States”, activates the following display:
One Unit Divert will allow the
Monitor to activate the divert relay
when (1) MPR E-Scan unit
contains a solids reading below the
divert point with no alarm present.
Two Unit Divert will allow the
Monitor to activate the divert relay
only when both MPR E-Scan units
contain solids readings below the
divert point with or without alarms.
In addition, the divert relay will be
activated if one unit contains a low
solids reading while the other unit
is purging.
Trending enables the divert prediction indicator. This will generate a warning when a divert is
predicted to occur within the trend time set in Configuration Limits.
Printer allows printer to be turned off and not give warning light.
Printer Port allows the selection of type of printer to be used and port it will be connected to.
The choices are USB, Com3, or LPT1. The standard configuration is LPT1 for the printer
supplied with the MDS system.
Temp. Units selects RSP readout in Deg F or Deg C.
Configuration States Selection