Instruction manual

AMPDIO DRIVERS
Page 140
division of the train clock frequency.
Returns short: OK
or ERRHANDLE
ERRCHAN
ERRDATA
Prior Calls registerBoardEx
TCsetPeriodicPulseTrain
See Also TCfreePeriodicPulseTrain
TCchangePeriodicPulseTrainGate
TCchangePeriodicPulseTrainCount
TCchangePeriodicPulseTrainDuration
TCcontrolPeriodicPulseTrain
6.4.8.10 Change Periodic Pulse Train’s Pulse Count TCchangePeriodicPulseTrainCount
Changes the pulse count for the periodic pulse train generator (as set up by
TCsetPeriodicPulseTrain) to the specified value by altering the pulse frequency and the one-
shot duration. For a one-shot currently in progress, the wrong number of pulses may be
generated.
SUPPORTED IN VERSION 4.32 ONWARDS.
i = TCchangePeriodicPulseTrainCount (h, hPPT, pulseCount)
where h short: board handle as issued by the
registerBoardEx function.
hPPT short: periodic pulse train generator handle, as
issued by the TCsetPeriodicPulseTrain
function.
pulseCount short: number of pulses to output in each train.
Returns short: OK
or ERRHANDLE
ERRCHAN
ERRDATA
Prior Calls registerBoardEx
TCsetPeriodicPulseTrain
See Also TCfreePeriodicPulseTrain
TCchangePeriodicPulseTrainGate
TCchangePeriodicPulseTrainFreq
TCchangePeriodicPulseTrainDuration
TCcontrolPeriodicPulseTrain
6.4.8.11 Change Periodic Pulse Train’s Train Duration TCchangePeriodicPulseTrainDuration
Changes the one-shot duration for the periodic pulse train generator (as set up by
TCsetPeriodicPulseTrain) to the specified value by altering the pulse frequency and the one-
shot duration. For a one
-
shot currently in progress, the wrong number of pulses may be