Instruction manual
AMPDIO DRIVERS
Page 140
division of the train clock frequency.
Returns short: OK
or ERRHANDLE
ERRCHAN
ERRDATA
Prior Calls registerBoardEx
TCsetPeriodicPulseTrain
See Also TCfreePeriodicPulseTrain
TCchangePeriodicPulseTrainGate
TCchangePeriodicPulseTrainCount
TCchangePeriodicPulseTrainDuration
TCcontrolPeriodicPulseTrain
6.4.8.10 Change Periodic Pulse Train’s Pulse Count — TCchangePeriodicPulseTrainCount
Changes the pulse count for the periodic pulse train generator (as set up by
TCsetPeriodicPulseTrain) to the specified value by altering the pulse frequency and the one-
shot duration. For a one-shot currently in progress, the wrong number of pulses may be
generated.
SUPPORTED IN VERSION 4.32 ONWARDS.
i = TCchangePeriodicPulseTrainCount (h, hPPT, pulseCount)
where h short: board handle as issued by the
registerBoardEx function.
hPPT short: periodic pulse train generator handle, as
issued by the TCsetPeriodicPulseTrain
function.
pulseCount short: number of pulses to output in each train.
Returns short: OK
or ERRHANDLE
ERRCHAN
ERRDATA
Prior Calls registerBoardEx
TCsetPeriodicPulseTrain
See Also TCfreePeriodicPulseTrain
TCchangePeriodicPulseTrainGate
TCchangePeriodicPulseTrainFreq
TCchangePeriodicPulseTrainDuration
TCcontrolPeriodicPulseTrain
6.4.8.11 Change Periodic Pulse Train’s Train Duration — TCchangePeriodicPulseTrainDuration
Changes the one-shot duration for the periodic pulse train generator (as set up by
TCsetPeriodicPulseTrain) to the specified value by altering the pulse frequency and the one-
shot duration. For a one
-
shot currently in progress, the wrong number of pulses may be