X1 = 0
X2 = 4
Y1 = 8
Y2 = 12
Z1 = 16
Z2 = 20
chan1 short: timer/counter #1 channel number within
the chip (0, 1 or 2).
clk1 short: timer #1 clock source. One of the
following pre-defined constants may be used:
CLK_CLK = 0: external CLK(chan1) i/p
CLK_10MHZ = 1: 10 MHz
CLK_1MHZ = 2: 1 MHz
CLK_100KHZ = 3: 100 kHz
CLK_10KHZ = 4: 10 kHz
CLK_1KHZ = 5: 1 kHz
CLK_OUTN_1 = 6: OUT(chan1–1)
CLK_EXT = 7: external EXTCLK(chip1) i/p
gat1 short: timer #1 gate source. One of the
following pre-defined constants may be used:
GAT_VCC = 0: Enabled
GAT_GND = 1: Disabled
GAT_EXT = 2: GAT(chan1) external i/p
GAT_OUTN_2 = 3: /OUT(chan1–2)
chip2 short: address offset of timer/counter chip #2.
One of the following pre-defined constants may
be used:
X1 = 0
X2 = 4
Y1 = 8
Y2 = 12
Z1 = 16
Z2 = 20.
chan2 short: timer/counter #2 channel number within
the chip (0, 1 or 2).
clk2 short: timer #2 clock source. One of the
following pre-defined constants may be used:
CLK_CLK = 0: external CLK(chan2) i/p
CLK_10MHZ = 1: 10 MHz
CLK_1MHZ = 2: 1 MHz
CLK_100KHZ = 3: 100 kHz
CLK_10KHZ = 4: 10 kHz
CLK_1KHZ = 5: 1 kHz
CLK_OUTN_1 = 6: OUT(chan2–1)
CLK_EXT = 7: external EXTCLK(chip2) i/p
gat2 short: timer #2 gate source. One of the
following pre-defined constants may be used: