Datasheet

5
Suggested Oper. Voltage
Service (Sea Level) Test Voltage Test Voltage Test Voltage Test Voltage
Rating AC (RMS) DC (Sea Level) 50,000 Ft. 70,000 Ft. 110,000 Ft.
22D .0345 ± .0010 .141 .036 .094
20 .047 ± .001 .209 .044 .125
16 .067 ± .001 .209 .078 .141
12 .100 ± .002 .209 .116 .141
10 (Power) .137 ± .002 .355 NA NA
8 .181 ± .002 .490 NA NA
4 .281 ± .002 .490 NA NA
0 .453 ± .002 .585 NA NA
Test Current (Amps) Maximum Maximum
Contact Millivolt Drop MIllivolt Drop
Size Crimp Hermetic Crimp* Hermetic*
22D 5 3 73 85
20 7.5 5 55 60
16 13 10 49 85
12 23 17 42 85
10 (Power) 33 NA 33 NA
8 (Power) 46 NA 26 NA
480NA23 NA
0 150 NA 21 NA
CONTACT RATING
+ .004
– .000
+ .004
– .000
+ .004
– .002
+ .004
– .002
M 400 550 1300 VRMS 550 VRMS 350 VRMS 200 VRMS
N 300 450 1000 VRMS 400 VRMS 260 VRMS 200 VRMS
I 600 850 1800 VRMS 600 VRMS 400 VRMS 200 VRMS
II 900 1250 2300 VRMS 800 VRMS 500 VRMS 200 VRMS
SERVICE RATING
FINISH DATA
Non-Hermetic Shell Components
Service Class
Finish Military Proprietary
Anodic Coating (Non-Conductive) C RX**
F (Metal)
M (Composite)
W (Metal)
J (Composite)
Stainless Steel with Nickel Plate S RS
Stainless Steel K RK
Stainless Steel Y Y
Stainless Steel with Nickel Plate N YN
Hermetic Shell Components
Service Class
Material / Finish Military Proprietary
* When using silver plated wire.
Crimp Well Data Hermetic Data
Contact Nominal Min. Well
Size Well Diameter Well Depth Well Diameter Depth
Tri-Start
specifications
** Add Suffix (005) to part number.
Olive Drab Cadmium Plate Nickel Base
RF
RW
Electroless Nickel
Please note that the establishment of electrical safety factors is left entirely in the designer’s hands, since he is in the best position to know what peak voltage,