Datasheet
ENTERTAINMENT INTERCONNECT CATALOGUE - Amphenol Australia Pty Ltd Telephone 61 3 8796 8888 Fax 61 3 8796 8801
www.amphenolaudio.com
65
EP / AP / SP / HP SERIES
VALUE
STANDARD DATA
STANDARD DATA EP/AP
Number of contacts
Contact Arrangements
(Front view of pin insert)
3 4 5 6 8
GENERAL
CHARACTERISTICS
Wire Gauge - Stranded wire: 12AWG 12AWG 12AWG 12AWG 14AWG
Termination
UL94V-0Flammability
Complies with EU RoHS 2 Directive 2011/65/EUEnvironmental
SOLDER
1300V
100V
15A
1)
MECHANICAL
CHARACTERISTICS
Service Voltage RMS
Test Voltage AC RMS
ELECTRICAL
CHARACTERISTICS
2400V 3000V 1600V 1600V
460V 660V 200V 200V
CLIMATIC
CHARACTERISTICS
1)
Insulation Resistance
≥1000MΩ
Typicial Contact Resistance
≤3mΩ
Mechanical operations
Current carrying capacity 20A 20A 20A 20A
Weight - EP 11 & 12 80g 84g 86g 86g
(0.176lb) (0.185lb) (0.189lb) (0.189lb)
Weight - EP 13 & 14 48g 50g 54g 54g
(0.105lb) (0.110lb) (0.119lb) (0.119lb)
Weight - AP 11 & 12 N/A 42g 44g 44g
(0.092lb) (0.097lb) (0.097lb)
Weight - AP 13, 14, 21 & 22 N/A 26g 30g 30g
(0.057lb) (0.066lb) (0.066lb)
1000 mating cycles
Typical Cable retention force 22Kg to 44Kg (50lb to 100lb) - Dependant on cable material and diameter
Protection Class
Operating Temperature
IP40
-25˚C to +75˚C (-13°F to +167°F)
Not suitable for domestic applications above 50V
Approximate weight only, does not include packaging. Please contact us for exact weight for shipping purposes.
2)
2)
2)
2)
Rev 3 - 03/2013
2)
86g
(0.189lb)
54g
(0.119lb)
44g
(0.097lb)
28g