Latched/Continuous Status Field MSR Diagnostic Status Information
163 3 Transport Fault: +24V Power Supply - Set when +24 volt power
supply varies by more than 2.44 volts.
164 7 Transport Fault: AST Not Standard - Set when Automatic Scan
Tracking is not set for normal operation (test mode only).
164 6 Transport Fault: Auto Record Optimize Failed - Set when auto record
current optimize feature cannot set record currents within allowable
limits to achieve optimization.
164 5 Transport Fault: Head #1 RF Low - Set when signal reproduced by
head #1 is below an acceptable level.
164 4 Transport Fault: Head #2 RF Low - Set when signal reproduced by
head #2 is below an acceptable level.
164 3 Transport Fault: Head #3 RF Low - Set when signal reproduced by
head #3 is below an acceptable level.
164 2 Transport Fault: Head #4 RF Low - Set when signal reproduced by
head #4 is below an acceptable level.
164 1 Transport: Scanner Timeout - Set when scanner stops after timeout
expires.
164 0 Transport: Still-Frame Timeout - Set when tape is unwrapped from
scanner after timeout expires.
165 7 Transport Fault: Linear Tracks Update Fault - Set when recording if
Electronics does not send linear tracks update message for every
Double Frame of edit period, or ADFN in message is not in sequence
with previous update, or ADFN in message is not correct for current
tape position.
165 6 Transport Fault: Unknown Logic State - Set during injection/ejection
if thread/unthread software state machines enter an unknown state.
This should never occur unless there is a hardware failure (e.g. CPU,
RAM, ROM).
165 5-0 Reserved