User Guide

5-36 Ampex 1308910-01
Model No.
Running Head
acl_setparam_library ACL Application Programmer’s Guide
A DST 712 and 812 ACLs will move the tape cartridge to a drive
or IMEX bin, but not to a storage bin.
When the Barcode Required configuration parameter is set to off,
the ACL does not restrict movement of a tape cartridge that does not
have a readable barcode ID.
ENVIRONMENT
The ACL management utilities use the following environment variable.
$ACL_DEV
Specifies the device special file to use when you omit the -f option.
EXIT STATUS
The ACL management utilities use the following exit status codes:
0 Operation succeeded.
nonzero Operation failed.
See ““Exit Status” on page 5-7” for information on how to determine the cause of a failure.
Writer_Note: I changed the description of the following example. Please verify that leaving a field
blank retains the current configuration parameter setting.
EXAMPLES
Set the Auto Store configuration parameter to on.
acl_setparam_library -aclparam :1::::
SEE ALSO
ACL Utilities Overview” on page 5-1
“acl_getparam_library” on page 5-19
“aclSetParam” on page 4-26