User Guide

Ampex 1308910-01 5-21
ACL Utilities acl_getparam_library
When the Barcode Required configuration parameter is set to
off, the ACL does not restrict movement of a tape cartridge that
does not have a readable barcode ID.
%auto_import Displays the current setting of the Auto Import
%v_auto_import configuration parameter (DST 712 and DST 812):
1 or Enabled indicates that the parameter is set to on.
0 or Disabled indicates that the parameter is set to off.
The ACL detects the presence of a tape cartridge when it is
inserted into an IMEX bin. When the Auto Import configuration
parameter is set to on, the ACL automatically transfers the
cartridge to the next available storage bin.
When the Auto Import configuration parameter is set to off, this
functionality is suppressed and the initiator must use the
acl_move_tape or acl_move_volume utility to transfer the tape
cartridge to a storage bin (or tape drive).
ENVIRONMENT
The ACL management utilities use the following environment variable.
$ACL_DEV
Specifies the device special file to use when you omit the -f option.
EXIT STATUS
The ACL management utilities use the following exit status codes:
0 Operation succeeded.
nonzero Operation failed.
See the ““Exit Status” on page 5-7” for information on how to determine the cause of a failure.
Writer_Note: We should show a typical output for the example.
EXAMPLES
Display the current settings of all configuration parameters in verbose style.
acl_getparam_library -stdout "auto eject: %v_auto_eject\nauto audit
override: \%v_auto_audit_override\nbarcode required:
%v_barcode_enable\nauto import: %v_auto_import"
The output might look like: