User Guide

Ampex 1308910-01 5-17
ACL Utilities acl_errlog_library
-count
<count_specification>
Specifies the number of entries to retrieve from the ACL error/event log. The maximum value
is 1000. The most recent entries are displayed first.
You must provide -count <count_specification> and -stdout <output_spec> arguments for
this utility (except when using the -help argument).
-stdout
<output_spec>
Specifies the output stream written to stdout. You must provide -count <count_specification>
and -stdout <output_spec> arguments for this utility (except when using the -help argument).
The -stdout <output_spec> argument supports the following keyword:
%elog.
ENVIRONMENT
The ACL management utilities use the following environment variable.
$ACL_DEV
Specifies the device special file to use when you omit the -f option.
EXIT STATUS
The ACL management utilities use the following exit status codes:
0 Operation succeeded.
nonzero Operation failed.
See ““Exit Status” on page 5-7” for information on how to determine the cause of a failure.
EXAMPLES
Display the 5 most recent error/event log entries.
acl_errlog_library -count 5 -stdout %elog
This may look like this:
05/12/1998 12:03:36:19 Command: Log sense page 57
05/12/1998 12:03:00:55 Command: Log sense page 57
05/12/1998 11:59:34:14 Command: Inquiry
05/12/1998 12:03:36:07 Command: Read element status
(num/type/start) 901
05/12/1998 12:03:36:04 Command: Read element status
(num/type/start) 901