User Guide

4-14 Ampex 1308910-01
Model No.
Running Head
aclGetParam ACL Application Programmer’s Guide
The ACL detects the presence of a tape cartridge when it is inserted
into an IMEX bin. When the Auto Import configuration parameter is
set to on, the ACL automatically transfers the tape cartridge to the
next available Storage Element, starting from address 1000.
When the Auto Import configuration parameter is set to off, this
functionality is suppressed and the initiator must use the
aclMoveCartridge() or aclMoveVolume() function to transfer the
tape cartridge to a storage bin (or tape drive).
RETURN VALUES
The return value is DST_SUCCESS (0) or DST_FAILURE (-1). See “Return Values” on page
4-2, for information on how to determine the cause of a failure.
SEE ALSO
“libacl Overview” on page 4-1
“aclSetParam” on page 4-26
“acl_getparam_library” on page 5-19